EloStar Master 3X0 / 4X0 / - smart
System Description
Manual V.1.03H
20
3.3.5
Optional Functions with Version EM13
This firmware version is compatible to FlatControl only. If not marked otherwise, the
functions are available also for systems with QPad. The version of the firmware can be
displayed via menu
Status / Info
. See page 92. Some of these functions can be
programmed with the optional configuration software PC-Software QPadComm /
TwinComm.
Change of display colour
Change to blue display.
Reset the locks
After a new start, lock address 0,1,2,3 can be set to 0 via menu selection (hotkey).
Hotkeys
New h
otkey „Access counter set to 0 (only 1 time/day)”, with which you can reset the
access counter and a changed order of default hotkeys ex works.
New real time clock (RTC)
More accurate RTC that keeps data up to 15 days without current.
„
Special e
ntrance“ can be
configured via TwinComm
Via TwinComm
, „Special entrance“ can be configured. By defining a opening period or /
and a maximum number of openings, the capability of users to open can be restricted.
With FlatControl only.
Automatic copying of manager code
When changing the manager code, the new manager code automatically is copied from
lock 1 to tock 2.
Display of confirmation code
The confirmation code is on display only with the system closed and the bolt work
(switch) closed; when open, 4 asterisks (*) are on display instead.
Display of serial number
Serial number always on display during new start (new start of supply of current).
User group restrictions also during release period
User group restrictions are valid also during release period after opening delay.
Menus
„
Deregister
“: Transfer
of PIN code and code card
The PIN code / code card
setting of menu “Deregister” can be transferred to other locks
automatically.
Dependent OTC via TwinComm
With dependent OTC (single use code), there is the option to configure that every user
entitled to use OTC via user matrix is assigned to using OTC via TwinComm. With
FlatControl only.
Separate logging of the correct code of OTC with dependent OTC input
Separate logging of the correct code input of OTC with dependent OTC.