Switch off the silent alarm
Function not UL evaluated. Locally (via
tab “Settings”, tab sector “TwinAlarm”, field
“Silent alarm” in TwinComm), you can configure whether users should be able to trigger
silent alarm / duress alarm or not. With silent alarm deactivated, nobody can open with
the alarm code.
Data export and - import for selected users
whether the system is open or closed
The Import / Export menu of the display of the operating unit is available and can be
used whether the system is opened or closed / locked. With other parameters set
accordingly, every user with valid PIN code can export configuration data.
Every user with box
„Service“ marked (via user matrix PC software) can import
configuration data.
Opening after unlocking delay during release time
Locally via PC software (via tab
“Settings”, tab sector “Dual code”, field “4-eyes (release)”
in TwinComm, for example), you can configure whether users should be able to open
locks during the release time (following an unlocking delay) only if they work in pairs.
With this option selected, only one user starts to trigger the opening process.
Setting „2
-
eyes“ overrides setting „Parallel code“
Locally (via
box “2-eyes” of the user matrix in the PC software), you can configure that a
user can open the two locks of a system even with optio
n “Parallel code” selected as
part of the system settings.
Users can be blocked after the validity of their code has expired
Locally via PC software (via
tab “Settings”, tab sector below “Code validity expiration”,
field
“User blocked after code aging” in TwinComm, for example), you can configure
whether and after how many months users are to be blocked and deleted after the
validity of their code has expired.
Operating unit changes to sleep mode earlier
With users not pressing any keys and without ongoing internal processing, the operating
unit changes to sleep mode a few seconds after inactivity.
Cutting an unlocking delay short
Excepted are alarm delays and blocked periods. Users can cut unlocking delays short
by pressing and holding the key CLEAR.
Immediate blocking
With the lock open or closed, you can program an immediate blocking for persons
assigned to a week program via selecting and holding menu key (with QPad) / selecting
key F2 of FlatControl. Once programmed, opening is blocked for all persons assigned to
the week program during the currently active time window. Upon the start of the next
week program, opening is possible again.
Blocked - / 0pening periods
With version EM11 and higher, 10 blocked - / opening periods are available.
Battery operation
As an alternative, the system can be battery operated instead of connected to mains
power supply.
Delays associated to week programs
You can define a specific opening delay, a specific alarm delay and a individual release
time for every week program.
Manager and master in user matrix and protocol
System manager and lock master have their own specific listings / entries within the user
matrix and the protocol.
Special days can be defined as “open days”
You can define special days as open days on which opening is possible.
4-Eyes (Opening lock 2)
Separate configuration for the opening of the second lock with dual code only.