31
Fig. 17: Dimensions QPad, view 1-3
View 1)
Dimensions of the operating unit
View 2)
Depth of the operating unit,
straight
front version
View 3)
Depth of the operating unit, version at an
angle
Caution
Applying too much force may cause damage to the operating
unit.
Fasten the screws using a max. torque of
1 Nm
.
2.
At the mounting points drilled by you, put the attachment screws M4x8 through the
rear of the operating unit into the safe wall and fasten the screws.
The arrow below the mark TOP in the centre of the back of the housing points
upwards.
See separate Assembly Sheet
“Option box RFID”. Attach option box to operating
unit next to it via snap rivets, if required. Use adhesive foil for attachment.
3.
Fasten the EMD screw (screw used for external manipulation detection, in short
EMD)
- M3x6 (straight version membrane keypad) /
- M3X16 (slanted version membrane keypad)
at position C in fig. below and test whether the lift off contacts are electrically
connected (see fig. 20 below) when the housing is closed.
With glass versions, use the metal spacer sleeve for the EMD screw.
4.
Insert the jumper cap wire harness (with
„straight“ front, see figure ‘Terminals of
‘, item 11 on page 33) or insert the housing harness (with slanted front).
5.
With the bus cables, form a loop behind the PCB in order to create clearance and
lead the cables connected to the operating unit through the cable lead-through you
made.
6.
Connect bus cable A to socket A at the QPad PCB. Make sure the plugs connect
properly.
7.
If required, connect further extensions (see Fig.
‘Terminals of QPad‘ below) of the