EloStar Master 3X0 / 4X0 / - smart
System Description
Manual V.1.03H
17
CIT 2-eyes
Option that users can open alone with flexible OTC / single-use code even if opening
with dual code is configured.
Emergency power check
Optional check of the battery voltage and, if required, an issue of warning messages.
Closing: Automatic locking DS FlatControl
Option that the door contact of the operating unit makes the lock close automatically
immediately after closing of the door / bolt work.
Single-use code - / OTC functionality
Section for the configuration of the use of flexible OTC / single-use code.
Hotkeys
You can define special certain keys of the operating unit as “hotkeys”. Selecting these
keys when activating the operating unit will have the display show the associated menu
immediately. Keep the hotkeys depressed for a second or repeat depressing them after
the activation.
Extended User Matrix
The optional users 226 and 227 have been added to the user matrix of the optional
PC software. Additionally, there is the option of generating and using templates for the
configuration of user rights.
OTC (single use code) dependent
Not evaluated by UL. So called dependent OTC (single use code) can be used with
versions up to EM22.
See section „Operation with OTC Dependent (up to EM22)“ on
p.52.
Additional m
enu “Settings/ Lock system” within d
isplay of operating unit
Optional menu with sub menu
s „Dual code“ (4-eyes-principle), „Parallel code“, „Forced
sequence“, „Opening delay“ and „Week program“. Via Menu „ Lock system“, the
parameters listed above can be set via operating unit.
Interlocking (interdependent locking)
Function for safes with two access doors /bank / CIT) or for door of strong room and safe
door.
Interlocking internal active
Mark this box in order to activate the internal interlocking. This option makes sure one
door (bank door or CIT/WTU door) will be blocked whenever the other one is in use or
a safe door will be blocked when a strong room door is open and vice versa.
Interlocking external active
Mark this box in order to activate the external interlocking. With this option the lock
changes the status already at the time of code input so that nobody can enter the access
room afterwards.
System block / - release
Global release
Tick [AE: Mark] this box in order to activate the global release. This option makes the
global release / system block apply for the whole system. Select at least one week
program in order to define the periods of system block - / - release.
WP1 /WP2 /WP3 / WP4 / WP5
Tick [AE: Mark] this box in order to activate the week programs 1-5. By doing this with
“Global release” activated, you make sure the selected week programs apply for the
complete system and for all of its users independent of whether users are assigned to
week programs or not.