background image

Form 57033 Rev. A

01-05-2004

VIP 5500 OPEN ARCHITECTURE MORTISE LOCK

INSTALLATION MANUAL

5500 MORTISE  LOCK

AUTOBOLT

5500 MORTISE  LOCK

STANDARD

The VIP 5500 series lock is a microprocessor controlled, electromechanical locking system.
It is an open architecture product designed to interface with 3rd party panels encompassing
all the features of the lock, reader, door status and egress (rex/request to exit) indication in
one fire-rated piece of hardware. The 5100 employs a heavy-duty mechanical design tested
and complying with ANSI/BHMA grade 1 standards for performance and reliability. It is pow-
ered by 12 or 24 volts DC with only four wires required - two for power and two for commu-
nications. The lock communicates with a PIB (panel interface board) which communicates
with the panel as if it were separate components of an access control system.

Operationally, the outside lever is normally locked and the inside lever always retracts the
bolt to allow egress. Electronic access control is achieved by entering an”Access Credential”
(magnetic stripe card or Prox fob or card). The panel controls the lock through the PIB.

Please refer to all instruction manuals involved in the installation before you begin. 

Functions:

VIP 5594-FSA: 

(1” AutoBolt) - Fail Safe (unlocked)

VIP 5594-FSE: 

(1” AutoBolt) - Fail Secure (locked)

VIP 5596-FSA: 

(3/4” latch) - Fail Safe (unlocked)

VIP 5596-FSE: 

(3/4” latch) - Fail Secure (locked)

Models:
MG:

Magnetic stripe card reader

PX:

HID Prox card reader

Standard Monitoring Switches:
DSM:

Provides door status via data link to panel interface

KSM:

Provides mechanical key use events via data link to panel interface

REX:

Provides indication of inside lever use for request to exit input via data link 

to panel interface

Options:
T3:

Track 3 card reader (data must be ABA track 2 format) - MG only

EXT:

exterior use option - MG only (PX model has this standard)

KD:

Keyed Different, includes Schlage Everest cylinder

KA:

Keyed Alike, includes Schlage Everest cylinder

LC:

Less Cylinder

SLB:

2-3/4” backset, 1/2”  latch bolt

OLB:

2-3/8” backset, 1/2” latch bolt

ELB:

2-3/4” backset, 3/4” latch bolt

BEFORE YOU BEGIN:

Standard units are shipped from the factory to fit 1-3/4” doors. Verify the door thickness. If the door is not 1-3/4” thick, verify
that the door thickness option was ordered or consult factory.

PRE-INSTALLATION CHECK:
AN OPEN ARCHITECTURE SYSTEM REQUIRES AT LEAST THREE COMPONENTS - A PANEL INTERFACE BOARD (PIB), AN
ACCESS CONTROL PANEL (BY OTHERS) TO WHICH THE PIB IS CONNECTED AND THE VIP LOCK. SEE DOCUMENTATION FOR
THE ACCESS CONTROL PANEL/SOFTWARE THIS LOCK WILL BE USED WITH FOR ANY PRE-INSTALLATION TESTING
REQUIREMENTS AND REMEDIES. REFER TO THE WIRING INFORMATION INCLUDED WITH THE PIB FOR MORE INFORMATION.

PIB

PX

MG

Door Thickness Kits:

Available in 1/8” increments from 1-3/8” to 2-1/2”

This device complies with part 15 of the FCC rules. Operation is sub-
ject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including any interference that may cause undesired opera-
tion. Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate
the equipment.

Summary of Contents for VIP 5500 Series

Page 1: ...door status via data link to panel interface KSM Provides mechanical key use events via data link to panel interface REX Provides indication of inside lever use for request to exit input via data link to panel interface Options T3 Track 3 card reader data must be ABA track 2 format MG only EXT exterior use option MG only PX model has this standard KD Keyed Different includes Schlage Everest cylind...

Page 2: ...ypad reader will be on Line up the correct reference lines on the template with the edge of the door depending on the hand see paper template The centerline on the door should line up with the vertical centerline of the template Use the paper template to mark all holes Though the paper template is the preferred way to prep the door the dimensions below may be used if a paper template is not availa...

Page 3: ...DELS REQUIRE WIRING TO BE RUN TO THE MORTISE POCKET FROM THE HINGE SIDE BELOW IS A SUGGESTED WAY TO DO THIS A DOOR CORD OR ELECTRIC HINGE OR TRANSFER DEVICE MUST BE USED TO GET WIRING FROM THE FRAME TO THE DOOR NOTE THAT WHEN USING AN ELECTRIC HINGE IT IS RECOMMENDED THAT THE POWER WIRES BE DOUBLED OR TRIPLED UP ON BOTH THE POSITIVE AND GROUND LEGS TO AVOID SIGNIFICANT VOLTAGE DROP THROUGH THE THI...

Page 4: ...ck washer into place with tab on top facing out as shown below D Using nut tool provided tighten nut onto cylinder E Line up nearest notch on nut with tab on lock washer and bend tab into notch using nut tool so nut is secure F Install exterior gasket if used G Install upper and lower standoffs CYLINDER RECOMMENDED CAM SCHLAGE EVEREST P N B502 948 SCHLAGE CLASSIC P N B502 191 NUT TOOL EXTERIOR GAS...

Page 5: ...n bolt so bolt can be removed C Rotate bolt and reinstall on to shaft Do not remove spring D Apply thread locking compound to set screw Loctite 242 recommended E Install and tighten set screw from other side as shown F Remove change pin 5 32 SOCKET CAP SCREW LOCTITE 242 RECOMMENDED OUTSIDE ESCUTCHEON OUTSIDE HANDLE CHANGE PIN LOCK CASE 5 64 HEX WRENCH BOLT AUTOBOLT SHOWN TO CHANGE HAND OF LEVERS A...

Page 6: ... WIRE THROUGH WIRE HOLE TOWARD INSIDE OF DOOR AS SHOWN 4 INSTALL STRIKE BOX AND STRIKE 5 INSTALL LOCK CASE Install lock case into edge of door If the lock has the DSM switch feed the wire harness though the 3 4 hole as shown below Secure to door with 12 24 combination screws IMPORTANT Strike included with lock MUST be used for proper operation of mortise lockset ...

Page 7: ...ps head screws on lower standoffs Note that the cam on the outside escutcheon must be positioned with the dot at the 6 o Clock position and outside spindle must be inserted as shown in details NOTE Battery Powered inside baseplate shown OUTSIDE SPINDLE MUST BE INSERTED AS SHOWN SOCKET CAP SCREW WASHERS 5 32 HEX WRENCH BASE PLATE ASSEMBLY PASS WIRING HARNESS THROUGH 1 HOLE IN DOOR PHILLIPS HEAD SCR...

Page 8: ...e that latch retracts fully IMPORTANT See PIB manual for additional connecting instructions SHIELD DATA A DATA B GROUND V 1 0A 12VDC 0 5A 24VDC OUTSIDE MAIN HARNESS CONNECTION OFF PARKED ON TERMINATION RESISTOR 1 LOCK ADDRESS SEE CHART 2 LOCK ADDRESS SEE CHART 3 ALWAYS SET TO OFF 4 ALWAYS SET TO OFF 5 OFF FAIL SECURE FSE ON FAIL SAFE FSA 6 OFF ALL MG LOCKS ON ALL PX LOCKS 7 ALWAYS SET TO OFF 8 ALW...

Page 9: ...NSTALL INSIDE SPINDLE BATTERIES AND INSIDE ESCUTCHEON A Assemble spring onto inside spindle as shown install spindle into cam in lockset Note that the flat side faces away from the door See detail B Install inside escutcheon making sure that the inside spindle engages the lever cam While installing plug in REX switch connector C Test operation of inside lever to make sure that latch retracts fully...

Reviews: