EloStar Master 3X0 / 4X0 / - smart
Operation
Manual V.1.03H
97
7.15.5
Locking the System despite Defect Bolt Work Contact
In case you have connected a circuit for a bolt work contact via EloXT II, you
still can lock the system once even with the bolt work contact being defect.
Perform the steps described below and lock the system.
1.
Unlock the system by opening lock 1 or by opening all locks.
See paragraph
‘System State’ on page 50.
2.
If the display of the operating unit is blank, press key
Enter
.
The system tests its status. Date and time are on display.
3.
With key
<
or
>
select
Service
and press key
Enter
.
Service | Reset
is on display.
4.
With
<
or
>
select
1x bolt work
and press
Enter
.
1x bolt work | *=yes *=no
is on display.
5.
With
<
or
>
select
yes
and press
Enter
.
1x bolt work | Saved
is on display. You can lock the system once even
though the bolt work contact is defect.
6.
Close all locks in the system.
Also see the instructions ‘Close the Lock…’.
The system is locked.