Appendix A Parameter Table
- 144 -
Para.
No.
Para. Name
Setting Range
Default
Property
B0-05 Maximum linear speed 0.1 to 6500.0 m/min
1000.0 m/min
☆
B0-06
Minimum linear speed
for winding diameter
calculation
0.1 to 6500.0 m/min
20.0 m/min
☆
B0-07
Winding diameter
calculation method
0: Calculated based on linear speed
1: Calculated based on accumulative
thickness
2: AI1
3: AI2
5: Pulse input (DIO1)
0
★
B0-08
Maximum winding
diameter
1 to 6000.0 mm
500.0 mm
☆
B0-09
Reel diameter
1 to 6000.0 mm
100.0 mm
☆
B0-10 Setting channel of
initial winding diameter
0: B0-11 (Initial winding diameter 1)
to B0-13 (Initial winding diameter 3)
1: AI1
2: AI2
0
★
B0-11 Initial winding
diameter 1
1 to 6000.0 mm
100.0 mm
☆
B0-12 Initial winding
diameter 2
1 to 6000.0 mm
100.0 mm
☆
B0-13
Initial winding
diameter 3
1 to 6000.0 mm
100.0 mm
☆
B0-14 Current winding
diameter
1 to 6000.0 mm
100.0 mm
☆
B0-15
Winding diameter filter
time
0.00s to 10.00s
5.00s
☆
B0-16 Winding diameter
change rate
0: Disabled
0.1 to 10.0 mm
1.0
☆
B0-17
Winding diameter
change direction limit
0: Disabled
1: Decrease inhibited during winding,
and increase inhibited during
unwinding
0
☆
B0-18 Winding diameter reset
during running
0: Disabled
1: Enabled
0
☆
B0-19 Pre-drive speed gain
-100.0% to 100.0%
0.0%
☆
B0-20 Pre-drive torque limit
source
0: F2-09 [Torque limit source in speed
control (motoring)]
1: Based on tension
1
★
B0-21 Pre-drive torque
correction coefficient
-100.0% to 100.0%
0.0%
☆