5 Quick Commissioning
- 65 -
Operation
Para.
No.
Parameter Name
Default
Commission
0: No function
1: Forward RUN (FWD)
2: Reverse run (REV)
3: Three-wire control
4: Forward jog (FJOG)
5: Reverse jog (RJOG)
6: Terminal UP
7: Terminal DOWN
8: Coast to stop
9: Fault reset (RESET)
10: RUN disabled
11: External fault normally open (NO) input
12: Multi-reference terminal 1
13: Multi-reference terminal 2
14: Multi-reference terminal 3
15: Multi-reference terminal 4
16: Terminal 1 for acceleration/deceleration time selection
17: Terminal 2 for acceleration/deceleration time selection
18: Frequency source switchover
19: UP and DOWN setting clear (terminal, operating panel)
20: Command source switchover
21: Acceleration/Deceleration inhibited
22: PID pause
23: PLC status reset
24: Wobble disabled
25: Counter input (DIO1)
26: Counter reset
27: Length count input (DIO1)