Appendix A Parameter Table
- 110 -
Para.
No.
Para. Name
Setting Range
Default
Property
F5-18 Relay output delay
0.0s to 3600.0s
0.0s
☆
F5-20
DIO1 output delay
0.0s to 3600.0s
0.0s
☆
F5-22
DO active mode
selection
0: Positive logic active
1: Negative logic active
Ones: FMR (DIO2)
Tens: Relay1
Hundreds: Reserved
Thousands: DIO1
Ten thousands: Reserved
0
☆
F5-23 AO mode selection
0: Voltage output
1: Current output
0
★
Group F6: Start/Stop Control
F6-00 Startup mode
0: Direct startup
1: Catching a spinning motor (AC
asynchronous motor)
2: Pre-excited startup (AC
asynchronous motor)
0
☆
F6-01 Mode of catching a
spinning motor
0: From stop frequency
1: From 50 Hz
2: From maximum frequency
0
★
F6-02 Speed of catching a
spinning motor
1 to 100
20
☆
F6-03
Startup frequency
0.00 to 10.00 kHz
0.00 Hz
☆
F6-04 Startup frequency
active time
0.0s to 100.0s
0.0s
★
F6-05 Startup DC injection
braking current
0% to 100%
0%
★
F6-06
Startup DC injection
braking active time/
pre-excitation active
time
0.0s to 100.0s
0.0s
★
F6-07
Acceleration/
Deceleration mode
0: Linear acceleration/deceleration
1: S-curve acceleration/deceleration
0
★
F6-08 Time proportion of
S-curve start segment
0.0% to (100.0% – F6-09)
30.0%
★
F6-09 Time proportion of
S-curve end segment
0.0% to (100.0% – F6-08)
30.0%
★
F6-10 Stop mode
0: Decelerate to stop
1: Coast to stop
0
☆
F6-11
Shutdown DC injection
braking/Zero servo
start frequency
0.00 Hz to maximum frequency
0.00 Hz
☆