Appendix A Parameter Table
- 95 -
Para.
No.
Para. Name
Setting Range
Default
Property
F0-17
Acceleration time 1
0.00s to 65000s
20.0s
☆
F0-18 Deceleration time 1
0.00s to 65000s
20.0s
☆
F0-19 Acceleration/
Deceleration time unit
0: 1s
1: 0.1s
2: 0.01s
★
F0-21
Frequency offset of
auxiliary frequency
setting channel for
main and auxiliary
calculation
0.00 Hz to maximum frequency (F0-
10)
0.00
Hz
☆
F0-22 Frequency reference
resolution
1: 0.1 Hz
2: 0.01 Hz
2
★
F0-23
Retentive of digital
setting frequency upon
stop
0: Not retentive
1: Retentive
0
☆
F0-25
Acceleration/
Deceleration time base
frequency
0: Maximum frequency (F0-10)
1: Frequency reference
2: 100 Hz
0
★
F0-26
Base frequency for UP/
DOWN modification
during running
0: Running frequency
1: Frequency reference
0
★
F0-27
Main frequency
reference coefficient
0.00% to 100.00%
10.00%
☆
F0-28 Auxiliary frequency
coefficient
0.00% to 100.00%
10.00%
☆
Group F1: 1st Motor Parameters
F1-00 Motor type selection
0: Common asynchronous motor
1: Variable frequency asynchronous
motor
2: Synchronous motor
0
★
F1-01 Rated motor power
0.1 to 1000.0 kW
Model
dependent
★
F1-02 Rated motor voltage
1 to 2000 V
Model
dependent
★
F1-03
Rated motor current
0.01 to 655.35 A (drive unit power ≤
55 kW)
0.1 to 6553.5 A (drive unit power > 55
kW)
Model
dependent
★
F1-04 Rated motor frequency 0.01 Hz to maximum frequency (F0-
10)
Model
dependent
★
F1-05 Rated motor speed
1 to 65535 RPM
Model
dependent
★