Appendix A Parameter Table
- 131 -
Para.
No.
Para. Name
Setting Range
Default
Property
FP-01 Parameter initialization
0: No operation
01: Restore factory parameters
except motor parameters, encoder
parameters, and F0-10 (Maximum
frequency)
02: Clear records
04: Back up current user parameters
501: Restore backup user parameters
502: Restore to factory setting (except
FD group and AF group parameters)
(supported by only dual-axis models)
0
★
FP-02 Parameter display
property
Ones: Selection of display of group U
0: No display
1: Display
Tens: Selection of display of group A
0: No display
1: Display
111
☆
FP-03
Selection of
individualized
parameter display
Ones: Selection of display of user-
defined parameters
0: No display
1: Display
Tens: Selection of display of user-
modified parameters
0: No display
1: Display
11
☆
FP-04 Selection of parameter
modification
0: Disabled
1: Enabled
0
☆
Group A0: Torque Control Parameters
A0-00 Speed/Torque control
selection
0: Speed control
1: Torque control
0
★
A0-01
Torque reference
source in torque
control
0: Digital setting (A0-03)
1: AI1
2: AI2
4: Pulse reference (DIO1)
5: Communication setting
6: MIN (AI1, AI2)
7: MAX (AI1, AI2)
(100.0% of the value corresponds to
the setting of A0-03)
0
★
A0-03
Torque digital setting
-200.0% to 200.0%
100.0%
☆
A0-04
Torque filter time
0 to 5.000s
0.000s
☆
A0-05 Speed limit digital
setting
-120.0% to 120.0%
0.00%
☆