5 Quick Commissioning
- 60 -
5 Quick Commissioning
Operation
Para.
No.
Parameter Name
Default
Commission
START
Before power on
Install and wire
the drive
Install and wire the units as explained in chapters 1 to 3.
Check UVW
wirings of power
supply and drive
units
-
Restore
parameters
FP-01 Parameter initialization
0
0: No operation
01: Restore factory parameters except motor parameters, encoder
parameters, and F0-10 (Maximum frequency)
02: Clear records
04: Back up current user parameters
501: Restore backup user parameters
502: Restore to factory setting (except FD group and AF group
parameters) (supported by only dual-axis models)
NOTE: It is recommended to "Restore default settings" before
commissioning the device.
Set motor
parameters
Motor Nameplate
*/%6$5*0/.0503
5:1& : 4 '3".&
10-&4 065165 )1 L8
70-5 7 1I )[ */4 '
".1 "
$0// : *1
31. #&"3*/(4
4&3*"-/0
854 ,(
F1-01 Rated motor power
Model
dependent
Unit: kW
F1-02 Rated motor voltage
Model
dependent