Startup Operation
User Manual H12 / SCAMAX® 8x1 - Version 2019.12
3.4.1.
Power Supply / Main Switch
The Power Supply unit on the rear panel consists of power connector
and Main Switch.
For connect, the device should be turned off, i.e. the Main Switch set to
"0" and the supplied power cable connected to the earthed mains socket.
Via the Main Switch, the power supply is released to the scanner with "I".
The scanner is then in the energy saving mode.
Before turning off the Main Switch, make sure that any connected PC is
not in an active scan or driver dialog, as this may cause system errors that
require a restart of the PC
3.4.2.
USB3 Port for Scan Jobs
To connect the scanner to an external scan station, a device socket type USB 3.0 with a data rate of
up to 4000 Mbit/s is available on the Interface Bar (
Fig. chapter
). This has to be connected via the
supplied the USB3 device cable with the USB3 interface of the Scan PCs.
As usual with USB devices on Windows operating systems,
before
you connect the scanner to
your scanning PC for the first time, a matching USB device driver must be available there. Driver
installation will be covered in detail, in chapter
3.4.3.
USB Ports for Input Devices or Data Storage
For connecting commercial input devices (mouse / keyboard) or data storage (USB Stick / Flash Disk)
a total of three USB2 inputs are available on the Interface Bar (
Fig. chapter
As input devices are used only for internal changes to the central system unit of the scanner, it is not
examined further in this manual.
3.4.4.
Network Connection for Batch Transfer
If the internal scan client should be used, the export of scanned data can be made directly to a data
server on the network. For this the unit is connected to the network via the existing RJ45 jack (
Fig.
chapter
). This interface is a gigabit interface at a speed of up to 1000 Mbit/s. In order to ensure a
trouble-free connection, for the connection only high-quality, shielded Ethernet cable of category
5e or higher should be used.
Since the network interface is currently not supported, its configuration settings are not yet available.
Main Switch
Power Cord Socket
CAUTION
It is essential to make sure that the used socket has a functioning protective conductor.