XC161 Derivatives
Peripheral Units (Vol. 2 of 2)
The Analog/Digital Converter
User’s Manual
16-6
V2.2, 2004-01
ADC_X1, V2.1
ADCTS
[13:12] rw
Channel Injection Trigger Input Select
00
Channel injection trigger input disabled
01
Trigger input CAPCOM selected
10
Reserved
11
Reserved
Note: Reset value of bitfield ADCTS is 01
B
for
compatibility purposes.
ADCRQ
11
rwh
Channel Injection Request Flag
ADCIN
10
rw
Channel Injection Enable Control
ADWR
9
rw
Wait for Read Control
ADBSY
8
rh
Busy Flag
0
ADC is idle
1
A conversion is active
ADST
7
rwh
ADC Start/Stop Control
0
Stop a running conversion
1
Start conversion(s)
ADM
[6:5]
rw
Mode Selection Control
00
Fixed Channel Single Conversion
01
Fixed Channel Continuous Conversion
10
Auto Scan Single Conversion
11
Auto Scan Continuous Conversion
CALOFF
4
rw
Calibration Disable Control
0
Calibration cycles are executed
1
Calibration is disabled (off)
Note: This control bit is active in both compatibility
and enhanced mode.
ADCH
[3:0]
rw
Analog Input Channel Selection
Selects the (first) ADC channel which is to be
converted
Field
Bits
Type
Description