XC161 Derivatives
Peripheral Units (Vol. 2 of 2)
High-Speed Synchronous Serial Interface (SSC)
User’s Manual
19-18
V2.2, 2004-01
SSC_X, V2.0
19.3
Interfaces of the SSC Modules
In the XC161 the SSC modules are connected to IO ports and other internal modules
according to
The input/output lines of SSC0 are connected to pins of Ports P3, while the input/output
lines of SSC1 are connected to pins of Ports P1H. The three interrupt request lines of
each module are connected to the Interrupt Control Block.
Clock control and emulation control of the SSC Module is handled by the System Control
Unit, SCU.
Figure 19-8
SSC0 Module Interfaces
Figure 19-9
SSC1 Module Interfaces
SSC0
Module
MCA05461
Port P3
Control
System
Control
Unit (SCU)
SSC0DIS
f
SSC
Interrupt
Control
Block
SSC0_TIRQ
SSC0_RIRQ
SSC0_EIRQ
P3.9/MTSR0
P3.8/MRST0
MTX
MRX
STX
SRX
MSCLK
SSCLK
P3.13/SCLK0
SSC1
Module
MCA05462
Port P1H
Control
System
Control
Unit (SCU)
SSC1DIS
f
SSC
Interrupt
Control
Block
SSC1_TIRQ
SSC1_RIRQ
SSC1_EIRQ
P1H.2/MTSR1
P1H.1/MRST1
MTX
MRX
STX
SRX
MSCLK
SSCLK
P1H.3/SCLK1