XC161 Derivatives
Peripheral Units (Vol. 2 of 2)
TwinCAN Module
User’s Manual
21-55
V2.2, 2004-01
TwinCAN_X1, V2.1
Note: Modifying the contents of register AECNT/BECNT requires bit CCE = ‘1’ in register
ACR/BCR.
LETD
8
High
rh
Last Error Transfer Direction
0
The last error occurred while the corresponding
CAN node was receiving a message (REC has
been incremented).
1
The last error occurred while the corresponding
CAN node was transmitting a message (TEC
has been incremented).
An error during message reception is indicated without
regarding the result of the acceptance filtering.
LEINC
9
High
rh
Last Error Increment
0
The error counter was incremented by 1 due to
the error reported by LETD.
1
The error counter was incremented by 8 due to
the error reported by LETD.
0
[15:10]
High
–
Reserved; returns ‘0’ if read; should be written with ‘0’.
Field
Bits
Type Description