XC161 Derivatives
Peripheral Units (Vol. 2 of 2)
High-Speed Synchronous Serial Interface (SSC)
User’s Manual
19-3
V2.2, 2004-01
SSC_X, V2.0
Figure 19-2
Synchronous Serial Channel (SSC) Block Diagram
19.2.1
Operating Mode Selection
The operating mode of the SSC module is controlled by its control register SSCx_CON.
This register has a double function:
•
During programming (SSC disabled by SSCx_CON.EN = 0), it provides access to a
set of control bits
•
During operation (SSC enabled by SSCx_CON.EN = 1), it provides access to a set
of status flags
In the following, the layout of register CON is shown for both functions.
MCB05455
Baudrate
Generator
Clock
Control
SSC
Control Block
TIRQ
RIRQ
EIRQ
Transmit Interrupt
Receive Interrupt Request
Error Interrupt Request
Status Control
16-bit Shift
Register
16-bit Shift
Register
16-bit Shift
Register
Input/
Output
Line
Control
MTX
MRX
STX
SRX
f
SSC
to Pin
SCLK
to Pin
MTSR
to Pin
MRST
MSCLK
SSCLK