Interfaces of the ASC Modules
In the XC161 the ASC modules are connected to IO ports and other internal modules
according to
and
The input/output lines of ASC0 and ASC1 are connected to pins of Ports P3. The
6 interrupt request lines of each module are connected to the Interrupt Control Block.
Clock control and emulation control of the SSC Module is handled by the System Control
Unit, SCU.
Figure 18-21 ASC0 Module Interfaces
Figure 18-22 ASC1 Module Interfaces
Interrupt
Control
Block
ASC0
Module
MCA05452
Port P3
Control
System
Control
Unit (SCU)
P3.11/RxDA0
P3.10/TxDA0
S0TIRQ
S0ABIRQ2
S0RIRQ
S0EIRQ
S0TBIRQ
S0ABIRQ1
ASC0DIS
f
ASC
S0RxD
S0TxD
Interrupt
Control
Block
ASC1
Module
MCA05453
Port P3
Control
System
Control
Unit (SCU)
P3.1/RxDA1
P3.0/TxDA1
S1TIRQ
S1ABIRQ2
S1RIRQ
S1EIRQ
S1TBIRQ
S1ABIRQ1
ASC1DIS
f
ASC
S1RxD
S1TxD