182
E.
Touch save button. (Saves and sends calibration data to the ITL-40 when com-
plete.)
NOTES
If calibration fails, touch redo button (top right) of screen).
If there is no communication with ITL or if the calibration was done improperly, the
status will say
ERROR
in the bottom right corner of the screen.
Figure 151. Water Tank Calibration Step 3
5.4.2
Foam Tank A
The Foam A ITL-40 can only be calibrated the traditional way using the 1, 2, or 9 point calibration
in the ITL-40 manual (P/N 118253).
5.4.3
Foam Tank B
The Foam ITL-40 can only be calibrated the traditional way using the 1, 2, and 9 point calibration
in the ITL-40 manual (P/N 118253).
5.5.
Pump (Master Intake And Discharge) Pressure Alternate Calibration
Only use this procedure following MatrIIx pressure governor module replacement, otherwise cali-
brate the pump (master intake and discharge) pressure sensors using the Pressure Procedures,
SAM Control Center (paragraph 5.2.2.1, page 177)
DISENGAGE PUMP BEFORE PERFORMING CALIBRATION, OTHERWISE UNEX-
PECTED/UNDESIRABLE AUTOMATED OPERATIONS MAY OCCUR DURING CALIBRATION.
DO NOT EXCEED OPERATING PRESSURE LIMITS OF PUMP, INSTALLED PLUMBING,
HOSE(S), OR EQUIPMENT IN USE DURING CALIBRATION.
Always calibrate the pump (master intake and discharge) pressure sensors using a known good
and in-calibration calibrated pressure gauge to set the span. The sensors specification is ± 1.5 %
from 0 to 85 °C and ranges (linearly) from 1.5% to 2 % from 0 to –40 °C and from 85 to 125 °C.
Adjust the readout accordingly with respect to the actual pump temperature.
Perform the following to calibrate the pump (master intake and discharge) pressure.
A.
On SAM Pump Controller, touch and hold System Options icon until circle com-
pletes and Menu screen (Figure 152) appears.
Summary of Contents for Hale Sam
Page 2: ......
Page 37: ...17 Figure 14 SAM Blue CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 38: ...18 Figure 15 SAM Green CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 39: ...19 Figure 16 SAM Red CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 40: ...20 Figure 17 SAM System Drain And Pneumatic Diagram...
Page 41: ...21 Figure 18 SAM Speaks Diagram...
Page 42: ......
Page 58: ...38 THIS PAGE INTENTIONALLY BLANK...
Page 62: ...42 THIS PAGE INTENTIONALLY BLANK...
Page 192: ...172 THIS PAGE INTENTIONALLY BLANK...
Page 206: ...186 THIS PAGE INTENTIONALLY BLANK...
Page 220: ...200 THIS PAGE INTENTIONALLY BLANK...