157
Table 78. Hale SAM System Level SCR Table – CONTINUED
SYMPTOM
CAUSE
REMEDY
INTAKE MODULE SIGNAL LOST
- OPERATE REAR AND IN-LINE IN-
TAKES WITH PANEL SWITCHES
MIV–A Slave Lost Comm
(Controls Bottom And
T-port MIVs)
Check harness power connections
and circuit breakers. See para-
graph 4.3.5 (page 48) and sec-
tion 4.10.6 (page 115).
Check harness Green CAN bus con-
nections. Refer to FSG-PL-01503/
FSG-PL-01504 and industry standard
Deutsch connector practices.
Check harness Green CAN bus re-
sistance. See paragraph 4.16.3
(page 170).
Equipment Failure
Confirm both MIV–A modules are op-
erational and addressed correctly.
See paragraph 4.8.3 (page 97).
R&R failed SAM slave MIV–A module.
See paragraph 4.8.3 (page 97).
R&R failed SAM Valve Drive module.
See paragraph 4.8.4 (page 100).
INTAKE MODULE SIGNAL LOST
(MIV H-bridge Lost CAN Connection)
Wire Harness Discon-
nected/Damaged
Check harness power connections
and circuit breakers. See para-
graph 4.3.5 (page 48) and sec-
tion 4.10.6 (page 115).
Check harness Green CAN bus con-
nections. Refer to FSG-PL-01503/
FSG-PL-01504 and industry standard
Deutsch connector practices.
Check harness Green CAN bus re-
sistance. See paragraph 4.16.3
(page 170).
Equipment Failure
R&R failed MIV Drive Module. See
Summary of Contents for Hale Sam
Page 2: ......
Page 37: ...17 Figure 14 SAM Blue CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 38: ...18 Figure 15 SAM Green CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 39: ...19 Figure 16 SAM Red CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 40: ...20 Figure 17 SAM System Drain And Pneumatic Diagram...
Page 41: ...21 Figure 18 SAM Speaks Diagram...
Page 42: ......
Page 58: ...38 THIS PAGE INTENTIONALLY BLANK...
Page 62: ...42 THIS PAGE INTENTIONALLY BLANK...
Page 192: ...172 THIS PAGE INTENTIONALLY BLANK...
Page 206: ...186 THIS PAGE INTENTIONALLY BLANK...
Page 220: ...200 THIS PAGE INTENTIONALLY BLANK...