73
Refer to Table 27 for a list of tools and/or consumables required for this procedure.
Table 27. Barometer Sensor Tools And Consumables List
Standard Tools
Special Tools
Consumables
PPE (Eye and Hand Protection)
None
Shop Rag(s) (As Required)
7/16-in Wrench
Barometric Sensor
<See FSG-MNL-00212, Table 1,
Barometer Sensor>
Loctite 243 (or Equivalent)
Cable Ties (As Required)
If the barometric sensor fails or is damaged; replace the sensor as follows. See Figure 46.
Removal
A.
Tag and disconnect electrical connector.
B.
Using 7/16-in wrench, remove two (2) 1/4–20 X 1-1/2-in long machine screws
(each with one lock and one flat washer).
C.
Remove sensor.
Figure 46. Barometric Sensor R&R
Installation
A.
Align sensor with bracket.
B.
Apply Loctite 243 (or equivalent) to screw threads.