149
Figure 127. TS Outputs Screen – Pre-Prime #1 Active
4.15.3.2
Testing MIV Inputs
When an Input is triggered, the red bubble turns green. See Table 75 below for how to trigger the
corresponding inputs.
Table 75. MIV–A Input Testing
Button Name
Function
Comments
Button 1
LH MIV Button Input
Press and hold button
Button 2
RH MIV Button Input
Press and hold button
Button 3
RH BOT MIV Button Input
Press and hold button
Water Detect
Water Detect Input
See section 4.15.2 for water detect testing
If the desired function does not work verify power, harness connection, and CAN connection to
the component. If all three items are good, replace the component under test.
4.15.4
Testing Priming And Air Bleed Component (CAN Inputs)
Test ABV solenoid valves (CAN outputs) as follows.
A.
Select CAN Outputs.
B.
Select corresponding output to be tested. See Table 76 and Figure 128.
Table 76. Priming And Air Bleed Component Testing
Name
Air Bleed Output
MIV #1
Left Side MIV
MIV #2
Right-Side MIV
MIV # 3
Right Bottom MIV
MIV # 4
T-port MIV
MIV # 5
Left Bottom MIV
MIV # 6
Remote Mounted MIV
Summary of Contents for Hale Sam
Page 2: ......
Page 37: ...17 Figure 14 SAM Blue CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 38: ...18 Figure 15 SAM Green CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 39: ...19 Figure 16 SAM Red CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 40: ...20 Figure 17 SAM System Drain And Pneumatic Diagram...
Page 41: ...21 Figure 18 SAM Speaks Diagram...
Page 42: ......
Page 58: ...38 THIS PAGE INTENTIONALLY BLANK...
Page 62: ...42 THIS PAGE INTENTIONALLY BLANK...
Page 192: ...172 THIS PAGE INTENTIONALLY BLANK...
Page 206: ...186 THIS PAGE INTENTIONALLY BLANK...
Page 220: ...200 THIS PAGE INTENTIONALLY BLANK...