119
For legacy SAM systems utilizing RME or DSD pumps, the OEM locates the circuit breaker junc-
tion box utilizing the generic power stud/circuit breaker junction box bracket. See Figure 87.
Figure 87. OEM Located Legacy CB Junction Box
For legacy circuit breaker junction boxes, a maximum of two [2] AB Swing-out
TM
vales are con-
nected to each circuit breaker (MIVs may connect to the bus bar or have been externally powered
by the OEM). See Figure 88.
Figure 88. Legacy CB Junction Box Layout
Additionally, two in-harness circuit breakers were provided: a 15 Amp in-harness auto resetting
circuit breaker (unique to the legacy power system), and the 10 Amp (non resetting) circuit
breaker that is always provided to protect the audio amplifier.