T109: Drive Firmware Update Failure
Description
GUI Description: A tape drive firmware update failed.
Explanation: Tape drive firmware can be upgraded by using a FMR tape or
by downloading the firmware to a drive through the web user interface, the
I/O blade, or by means of a host utility. After the upgrade process is
complete, the library checks to verify that the drive reports the new firmware
version. If not, this ticket is generated. This ticket is generated only when the
user upgrades the drive firmware manually, and does not apply when the
drive firmware is upgraded by autoleveling.
Detection Scenario
After a drive firmware updated, the new version from the drive does not
differ from the old version.
Root Causes
v
The firmware image that was used to update the drive was the same as
what was already installed on the drive.
v
A firmware upgrade cartridge with an incompatible firmware version
(wrong generation, drive type, etc.) was used.
v
The firmware upgrade cartridge used did not have valid firmware.
v
The firmware image was successfully transferred to the drive, but was
corrupt or incomplete.
v
Error in drive communication or other drive specific error.
Possible FRU Replacement
Drive sled
Resolution
Perform “DR069: Resolve Drive Firmware Update Failure” on page 6-81.
T110: Drive Firmware Mismatch Detected
Description
GUI Description: A mismatch in tape drive firmware versions has been
detected.
Explanation: Each drive installed in the library is programmed with
firmware from the drive manufacturer. All drives in the library should have
the same firmware version. The library checks the library firmware version
upon initialization and again when a new drive is inserted. If the drive do
not all have the same firmware, a ticket will be generated. Rather than trying
to list all the differences, the ticket will simply instruct the user to look at the
System Information screen to identify which drives need to be updated.
Detection Scenario
On initialization, the library detects that not all drives have the same
firmware version.
Root Causes
A drive was installed that had a different firmware version than other drives
in the library.
Possible FRU Replacement
Drive sled
Resolution
Perform “DR070: Resolve Tape Drive Firmware Mismatch” on page 6-81.
6-46
TS3310 Tape Library Maintenance Information
Summary of Contents for System Storage TS3310
Page 2: ......
Page 6: ...iv TS3310 Tape Library Maintenance Information...
Page 8: ...vi TS3310 Tape Library Maintenance Information...
Page 18: ...xvi TS3310 Tape Library Maintenance Information...
Page 20: ...xviii TS3310 Tape Library Maintenance Information...
Page 22: ...xx TS3310 Tape Library Maintenance Information...
Page 28: ...1 6 TS3310 Tape Library Maintenance Information...
Page 76: ...3 14 TS3310 Tape Library Maintenance Information...
Page 92: ...4 16 TS3310 Tape Library Maintenance Information...
Page 196: ...6 94 TS3310 Tape Library Maintenance Information...
Page 242: ...7 46 TS3310 Tape Library Maintenance Information...
Page 378: ...8 136 TS3310 Tape Library Maintenance Information...
Page 382: ...9 4 TS3310 Tape Library Maintenance Information...
Page 390: ...10 8 TS3310 Tape Library Maintenance Information...
Page 396: ...A 6 TS3310 Tape Library Maintenance Information...
Page 415: ...Library Electrical Block a66mi038 Appendix C Library Diagrams C 7...
Page 416: ...Library Control Blade a66mi042 C 8 TS3310 Tape Library Maintenance Information...
Page 417: ...Library Control Blade Functions a66mi039 Appendix C Library Diagrams C 9...
Page 418: ...Accessor Control Block a66mi040 C 10 TS3310 Tape Library Maintenance Information...
Page 421: ...a66mi036 Appendix C Library Diagrams C 13...
Page 423: ...Library Power System a66mi044 Appendix C Library Diagrams C 15...
Page 424: ...a66mi043 C 16 TS3310 Tape Library Maintenance Information...
Page 484: ...D 60 TS3310 Tape Library Maintenance Information...
Page 494: ...E 10 TS3310 Tape Library Maintenance Information...
Page 498: ...F 4 TS3310 Tape Library Maintenance Information...
Page 504: ...G 6 TS3310 Tape Library Maintenance Information...
Page 520: ...H 16 TS3310 Tape Library Maintenance Information...
Page 526: ...X 6 TS3310 Tape Library Maintenance Information...
Page 529: ......
Page 530: ...Part Number 46X4072 Printed in USA GA32 0478 08 1P P N 46X4072...