Table D-11. Error codes on the Single-character Display (continued)
Error Code
Cause and Action
7
Media error. The tape drive determined an error occurred because of a faulty tape cartridge or an
invalid tape cartridge. Ensure the tape cartridge is the correct media type:
v
Ultrium -1 tape cartridges are not supported in Ultrium-4 tape drives.
v
Drive will not accept an expired Cleaning Cartridge.
v
Drive will not accept a WORM cartridge when running diagnostic tests in Maintenance Mode.
v
Drive will not write over existing datasets on a WORM cartridge. Ensure you are appending
datasets on WORM media rather than attempting to write over existing datasets.
If the tape cartridge is the correct media type, try another tape cartridge. If the problem occurs
with multiple tape cartridges, use the following procedure:
1.
If possible, run the tape cartridge in a different tape drive. If the operation in the other unit
fails and
6
or
7
displays, replace the media. If the operation succeeds, run “Function
Code 1: Run Drive Diagnostics” on page D-28.
Attention:
When you run the Test Cartridge & Media diagnostic, data on the suspect tape is
overwritten. Use only a scratch data cartridge to run the test.
v
If the diagnostic fails, replace the drive.
v
If the diagnostic succeeds, clean the drive head (refer to the drive cleaning operation in this
manual) and run “Function Code 1: Run Drive Diagnostics” on page D-28.
– If the drive diagnostic fails, replace the drive.
– If the drive diagnostic succeeds, perform the operation that produced the initial media
error.
The error code clears when you remove the tape cartridge or place the tape drive in maintenance
mode.
8
Interface problem. The tape drive determined that a failure occurred in the tape drive's hardware
or in the host bus. Refer to the problem solving information in this manual. If
8
was displayed
while running "Function Code 6: Host Interface Test":
1.
Verify the correct interface wrap tool was attached during the test. The test will fail if the
correct interface wrap tool is not attached.
2.
If the correct interface wrap tool was attached during the test, replace the drive. The error
code clears when you place the tape drive in maintenance mode.
Note:
The error code clears 10 seconds after the drive detected the error or when you place the
drive in maintenance mode.
9
Tape drive or RS-422 error. The tape drive determined that a failure occurred in the tape drive's
hardware or in the RS-422 connection. See “Function Code 7: Run RS-422 Wrap Test” on page
D-33 or refer to the Library procedures to isolate the problem to the drive. The error code clears
when you place the tape drive in maintenance mode.
Appendix D. Using Ultrium Drives
D-45
Summary of Contents for System Storage TS3310
Page 2: ......
Page 6: ...iv TS3310 Tape Library Maintenance Information...
Page 8: ...vi TS3310 Tape Library Maintenance Information...
Page 18: ...xvi TS3310 Tape Library Maintenance Information...
Page 20: ...xviii TS3310 Tape Library Maintenance Information...
Page 22: ...xx TS3310 Tape Library Maintenance Information...
Page 28: ...1 6 TS3310 Tape Library Maintenance Information...
Page 76: ...3 14 TS3310 Tape Library Maintenance Information...
Page 92: ...4 16 TS3310 Tape Library Maintenance Information...
Page 196: ...6 94 TS3310 Tape Library Maintenance Information...
Page 242: ...7 46 TS3310 Tape Library Maintenance Information...
Page 378: ...8 136 TS3310 Tape Library Maintenance Information...
Page 382: ...9 4 TS3310 Tape Library Maintenance Information...
Page 390: ...10 8 TS3310 Tape Library Maintenance Information...
Page 396: ...A 6 TS3310 Tape Library Maintenance Information...
Page 415: ...Library Electrical Block a66mi038 Appendix C Library Diagrams C 7...
Page 416: ...Library Control Blade a66mi042 C 8 TS3310 Tape Library Maintenance Information...
Page 417: ...Library Control Blade Functions a66mi039 Appendix C Library Diagrams C 9...
Page 418: ...Accessor Control Block a66mi040 C 10 TS3310 Tape Library Maintenance Information...
Page 421: ...a66mi036 Appendix C Library Diagrams C 13...
Page 423: ...Library Power System a66mi044 Appendix C Library Diagrams C 15...
Page 424: ...a66mi043 C 16 TS3310 Tape Library Maintenance Information...
Page 484: ...D 60 TS3310 Tape Library Maintenance Information...
Page 494: ...E 10 TS3310 Tape Library Maintenance Information...
Page 498: ...F 4 TS3310 Tape Library Maintenance Information...
Page 504: ...G 6 TS3310 Tape Library Maintenance Information...
Page 520: ...H 16 TS3310 Tape Library Maintenance Information...
Page 526: ...X 6 TS3310 Tape Library Maintenance Information...
Page 529: ......
Page 530: ...Part Number 46X4072 Printed in USA GA32 0478 08 1P P N 46X4072...