Troubleshooting Steps:
1.
Determine the specific cartridge and drive involved in the problem selecting the
Details
button.
2.
Retry the operation with the same cartridge in the same drive.
3.
If the retry attempt fails, try the operation to the same cartridge in a different drive.
4.
If the cartridge fails in more than one drive, retire the cartridge.
5.
It the cartridge tests OK, use a known good cartridge to test the drive by performing read/write operations from
a host, or by using a drive-specific utility. Contact Service for information on a drive utility for your specific
drive type.
6.
If the problem persists, gather a drive log afer the next occurrence of a Table Alert 5 or 6. Drive logs are
captured by using the
Service Library
→
Capture Drive log
menu selection from the Web User Interface. Contact
Service and provide the drive log.
DR046: Resolve Drive TapeAlert 8 - Suspect Data Grade Tape
Problem:
A drive has determined that a tape is not data grade and therefore data should not be written to it.
There can be several possible causes of this problem. Not all of the causes are genuine bad tapes, but in some cases
a cartridge should be retired.
Troubleshooting Steps:
1.
Attempting invalid operations with a cleaning cartridge may cause this problem. If the cartridge is a cleaning
cartridge, remove it from the host application inventory of valid data cartridges.
2.
If the cartridge is new, the tape may not have been formatted by the cartridge manufacturer. The drive will
automatically attempt to format the tape. If successful, all other operations to the tape will continue without
incident and this problem can be closed.
3.
On LTO cartridges, the cartridge memory chip may be corrupted. Using host application utilities, force a read of
the entire tape. When the tape is unloaded, the drive should repair the memory chip corruption. Monitor this
cartridge for reoccurrence of a Tape Alert 8. Retire this cartridge if the problem occurs again.
DR047: Resolve Drive TapeAlert 15 - Cartridge Memory Failure
Problem:
A drive has determined that a memory in cassette (MIC) has failed. This will reduce performance. The cartridge
memory may be repairable.
Troubleshooting Steps:
1.
Attempt to repair the cartridge memory by using host backup application utilities to read the entire tape. When
th tape is unloaded, the cartridge may be able to repair the tape memory.
2.
To verify that the cartridge memory is repaired, attempt to use the cartridge again for normal read/write
operations. If this cartridge fails again, retire the cartridge.
DR048: Resolve Drive TapeAlert 16 - Forced Eject
Problem:
A cartridge was manually ejected from a drive while it was actively reading or writing. This typically occurs when
a user is servicing the drive and has not stopped all host operations to the drive.
Troubleshooting Steps:
1.
Reload the tape cartridge back into the drive.
2.
Restart the failed host application.
6-78
TS3310 Tape Library Maintenance Information
Summary of Contents for System Storage TS3310
Page 2: ......
Page 6: ...iv TS3310 Tape Library Maintenance Information...
Page 8: ...vi TS3310 Tape Library Maintenance Information...
Page 18: ...xvi TS3310 Tape Library Maintenance Information...
Page 20: ...xviii TS3310 Tape Library Maintenance Information...
Page 22: ...xx TS3310 Tape Library Maintenance Information...
Page 28: ...1 6 TS3310 Tape Library Maintenance Information...
Page 76: ...3 14 TS3310 Tape Library Maintenance Information...
Page 92: ...4 16 TS3310 Tape Library Maintenance Information...
Page 196: ...6 94 TS3310 Tape Library Maintenance Information...
Page 242: ...7 46 TS3310 Tape Library Maintenance Information...
Page 378: ...8 136 TS3310 Tape Library Maintenance Information...
Page 382: ...9 4 TS3310 Tape Library Maintenance Information...
Page 390: ...10 8 TS3310 Tape Library Maintenance Information...
Page 396: ...A 6 TS3310 Tape Library Maintenance Information...
Page 415: ...Library Electrical Block a66mi038 Appendix C Library Diagrams C 7...
Page 416: ...Library Control Blade a66mi042 C 8 TS3310 Tape Library Maintenance Information...
Page 417: ...Library Control Blade Functions a66mi039 Appendix C Library Diagrams C 9...
Page 418: ...Accessor Control Block a66mi040 C 10 TS3310 Tape Library Maintenance Information...
Page 421: ...a66mi036 Appendix C Library Diagrams C 13...
Page 423: ...Library Power System a66mi044 Appendix C Library Diagrams C 15...
Page 424: ...a66mi043 C 16 TS3310 Tape Library Maintenance Information...
Page 484: ...D 60 TS3310 Tape Library Maintenance Information...
Page 494: ...E 10 TS3310 Tape Library Maintenance Information...
Page 498: ...F 4 TS3310 Tape Library Maintenance Information...
Page 504: ...G 6 TS3310 Tape Library Maintenance Information...
Page 520: ...H 16 TS3310 Tape Library Maintenance Information...
Page 526: ...X 6 TS3310 Tape Library Maintenance Information...
Page 529: ......
Page 530: ...Part Number 46X4072 Printed in USA GA32 0478 08 1P P N 46X4072...