Fixing a Solid Error with One Drive on a SAS Connection
1.
Verify that the power is ON to the drive.
a.
Verify that the library is powered ON.
b.
Verify that the power supplies (in the module containing the failing drive)
are ON.
c.
Verify that the drive is fully seated in the library chassis.
2.
Determine if the drive is experiencing a hang condition.
a.
If a cartridge is in the drive, press the unload button.
v
If the cartridge ejects, the drive does not have a hang condition, go to
step 5.
v
If the cartridge does not eject, go to step 3.
b.
If there is no cartridge in the drive, manually load a scratch cartridge into
the failing drive. If the cartridge loads, the drive does not have a hang
condition. Press the unload button to unload the scratch cartridge and go
to step 6.
3.
Press and hold the unload button for 20 seconds. The drive will save a dump
and go into a reboot, which allows communication to the drive. Do not cycle
power (power OFF then power ON) or you will lose the dump contents.
4.
Copy the Drive Dump with one of the following procedures
v
If the drive is no longer hung (cartridge can be unloaded), refer to
“Diagnostic and Maintenance Functions” on page D-26 and collect the
dump on a scratch (blank) cartridge.
v
If the drive is still hung, refer to “Using the ITDT SCSI Firmware Update,
Dump Retrieval and Drive Test Tool” on page 7-27 to secure the dump
using ITDT. Contact your next level of support to determine if they can use
this dump.
5.
If the problem continues to be in the drive, replace the failing drive sled. Refer
to “Drive Sled” on page 8-43. When complete, go to “End of Call” on page
7-44.
6.
Ensure that the SAS cables or interposers are plugged in and tightened at both
ends.
7.
Ensure that the drive element address is the same as the element address
being used by the host system. From the Operator Panel, select
Reports
→
Library Configuration
.
8.
If another SAS drive is available, do the following:
a.
Quiece the library from all activity and swap the drives.
b.
If the problem stays with the suspect drive, replace the drive sled.
c.
If the problem moves to the new drive, replace the SAS cable or interposer.
d.
If the problem still exists after performing the above procedures, suspect a
host system hardware or software problem. Refer to the service
documentation for the host system.
e.
Go to “End of Call” on page 7-44.
9.
If another SAS drive is not available to swap, replace the SAS cable or
interposer.
10.
If the problem still exists, replace the drive sled. If this does not fix the
problem, suspect that the problem is caused by host system hardware or
software. Refer to the service documentation for the host system.
11.
Go to “End of Call” on page 7-44.
D-58
TS3310 Tape Library Maintenance Information
Summary of Contents for System Storage TS3310
Page 2: ......
Page 6: ...iv TS3310 Tape Library Maintenance Information...
Page 8: ...vi TS3310 Tape Library Maintenance Information...
Page 18: ...xvi TS3310 Tape Library Maintenance Information...
Page 20: ...xviii TS3310 Tape Library Maintenance Information...
Page 22: ...xx TS3310 Tape Library Maintenance Information...
Page 28: ...1 6 TS3310 Tape Library Maintenance Information...
Page 76: ...3 14 TS3310 Tape Library Maintenance Information...
Page 92: ...4 16 TS3310 Tape Library Maintenance Information...
Page 196: ...6 94 TS3310 Tape Library Maintenance Information...
Page 242: ...7 46 TS3310 Tape Library Maintenance Information...
Page 378: ...8 136 TS3310 Tape Library Maintenance Information...
Page 382: ...9 4 TS3310 Tape Library Maintenance Information...
Page 390: ...10 8 TS3310 Tape Library Maintenance Information...
Page 396: ...A 6 TS3310 Tape Library Maintenance Information...
Page 415: ...Library Electrical Block a66mi038 Appendix C Library Diagrams C 7...
Page 416: ...Library Control Blade a66mi042 C 8 TS3310 Tape Library Maintenance Information...
Page 417: ...Library Control Blade Functions a66mi039 Appendix C Library Diagrams C 9...
Page 418: ...Accessor Control Block a66mi040 C 10 TS3310 Tape Library Maintenance Information...
Page 421: ...a66mi036 Appendix C Library Diagrams C 13...
Page 423: ...Library Power System a66mi044 Appendix C Library Diagrams C 15...
Page 424: ...a66mi043 C 16 TS3310 Tape Library Maintenance Information...
Page 484: ...D 60 TS3310 Tape Library Maintenance Information...
Page 494: ...E 10 TS3310 Tape Library Maintenance Information...
Page 498: ...F 4 TS3310 Tape Library Maintenance Information...
Page 504: ...G 6 TS3310 Tape Library Maintenance Information...
Page 520: ...H 16 TS3310 Tape Library Maintenance Information...
Page 526: ...X 6 TS3310 Tape Library Maintenance Information...
Page 529: ......
Page 530: ...Part Number 46X4072 Printed in USA GA32 0478 08 1P P N 46X4072...