background image

IBM

 

System

 

Storage

 

DR550,

 

Version

 

4.5

Problem

 

Determination

 

and

 

Service

 

Guide

 

GA32-0576-00

  

Summary of Contents for DR550

Page 1: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...

Page 2: ......

Page 3: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...

Page 4: ...ii DR550 Version 4 5 Problem Determination and Service Guide...

Page 5: ...ite 6 Placing a service call 6 Chapter 2 Using the monitor 7 User controls 7 Chapter 3 DR550 rack power control assembly 9 Model DR1 power control assembly power problems 9 Checking CB1 9 Checking CB2...

Page 6: ...M Server RAID Disk Controller rechargeable battery maintenance 95 Remove the DR550 SSAM Server service processor assembly 99 Replacing adapters 105 Field replacement for the DR550 File System Gateway...

Page 7: ...romagnetic Compatibility Directive 221 Germany Electromagnetic Compatibility Directive 222 People s Republic of China Class A Electronic Emission Statement 223 Taiwanese Class A warning statement 223...

Page 8: ...vi DR550 Version 4 5 Problem Determination and Service Guide...

Page 9: ...e 125 46 Replacing an EV DDM 126 47 DR2 Fiber Cabling Single Node from one Storage Controller to one SAN Switch to one SSAM Server and from one Storage Controller to one SSAM Server without mirroring...

Page 10: ...e System Gateway 2 153 82 DR1 Fiber Cabling Storage Controller 1 to Expansion drawer 1 1 154 83 DR1 Fiber Cabling Storage Controller 1 to Expansion drawer 1 1 and 2 1 154 84 DR1 Fiber Cabling SSAM Ser...

Page 11: ...LV configuration for 18 TB systems single and dual node 175 36 LV configuration for 24 TB systems single and dual node 175 37 LV configuration for 30 TB systems single and dual node 176 38 LV configur...

Page 12: ...205 69 LV configuration for 108 TB systems single and dual node 206 70 LV configuration for 120 TB systems single and dual node 208 71 LV configuration for 132 TB systems single and dual node 209 72 L...

Page 13: ...ignal cables are connected If possible disconnect all power cables from the existing system before you add a device v Use one hand when possible to connect or disconnect signal cables to prevent a pos...

Page 14: ...nal rack ambient temperatures will exceed the manufacturer s recommended ambient temperature for all rack mounted devices v Do not install a unit in a rack where the air flow is compromised Ensure tha...

Page 15: ...n do the following Lower the four leveling pads Install stabilizer brackets on the rack cabinet v If a long distance relocation is required restore the rack cabinet to the configuration of the rack ca...

Page 16: ...tion to guide you when using this product and in properly disposing of the product and its components Product Recycling and Disposal This unit must be recycled or discarded according to applicable loc...

Page 17: ...proper collection and treatment contact your local IBM representative Remarque Cette marque s applique uniquement aux pays de l Union Europ enne et la Norv ge L etiquette du syst me respecte la Direct...

Page 18: ...uet s conform ment aux directives europ ennes 2006 66 EC norme relative aux batteries et accumulateurs en usage et aux batteries et accumulateurs us s Les directives d terminent la marche suivre en vi...

Page 19: ...rial special handling may apply See the following Web site http www dtsc ca gov hazardouswaste perchlorate The foregoing notice is provided in accordance with California Code of Regulations Title 22 D...

Page 20: ...xviii DR550 Version 4 5 Problem Determination and Service Guide...

Page 21: ...on page 21 provides problem determination and service information for the DR550 File System Gateway Chapter 6 DR550 Storage Controller on page 43 gives information about problem determination and res...

Page 22: ...e you can get information about IBM products and services and find the latest technical information See Web sites on page xxii Software Maintenance All distributed software licenses include Software M...

Page 23: ...nline help v Referring to the online or printed documentation for the DR550 v Consulting the support Web page For the most recent information refer to Readme files or release notes for the DR550 stora...

Page 24: ...systems from the Product family menu then select DR550 from the Product menu You can also find product firmware and software downloads as well as associated driver code Access installation and techni...

Page 25: ...550 v IBM System Storage DR550 Introduction and Planning Guide v IBM System Storage DR550 Problem Determination and Service Guide this document v IBM System Storage DR550 User s Guide v IBM System Sto...

Page 26: ...ervice Agent User s Guide v IBM Server Storage Provisioning Tool Installation and User s Guide v IBM Director Troubleshooting and Support Reference These publications and additional information can be...

Page 27: ...International Business Machines Corporation Information Development Department GZW 9000 South Rita Road Tucson Arizona 85744 0001 U S A About this document xxv...

Page 28: ...xxvi DR550 Version 4 5 Problem Determination and Service Guide...

Page 29: ...y AIX V5 3 TL06 AIX V5 3 TL06 IBM Director or 5 20 2 preferred Management Interface software IBM Director or 5 20 2 preferred Management Interface software System Storage Archive Manager V5 4 System S...

Page 30: ...Are specific error messages or numbers associated with the problem for example on a screen or an operators panel Does IBM Director show any events or errors logged against any components Was there a...

Page 31: ...Did the user do anything different that made them notice the problem b When did it happen Does it always happen at the same time for example when the same application is run or a specific user access...

Page 32: ...AM Server service request number or other server problem indications Diagnostic Information for Multiple Bus Systems SA38 0509 Examine the system runtime error log See Viewing the AIX runtime error lo...

Page 33: ...eferenced in DR550 Storage Controller publications on page xxiii AIX AIX 5L for Power V5 3 Documentation CD LCD4 1144 Web based System Manager Administration Guide path and name is usr share man info...

Page 34: ...oblem occur and you need to contact IBM for service please call in as follows If you think the problem is hardware related contact IBM Service using the appropriate number When the call screening proc...

Page 35: ...damp cloth when necessary but be sure to unplug the LCD monitor first v Place the LCD monitor on a solid surface and treat it carefully The screen is made of thin glass with a plastic front surface a...

Page 36: ...r Button Turns on and off the monitor power t u v Moves the selector left and right on the OSD menu v Increases or deceases the value of the selected adjustment or selects the proper setting v Adjusts...

Page 37: ...hecking CB1 CB1 is the main circuit breaker for the PCA When CB1 is on pushed in AC power is being distributed When CB1 is off pulled out AC power is not being distributed Make sure that CB1 is pushed...

Page 38: ...ug the device power cords from the PCA 4 Unplug the jumper from connector J17 on the front of the PCA 5 Remove the PCA from the rack by removing two screws from each end of the PCA and slide out the P...

Page 39: ...er for the PCA When CB1 is on pushed in AC power is being distributed When CB1 is off pulled out AC power is not being distributed Make sure that CB1 is pushed in If the AC present LCD is off check th...

Page 40: ...nues replace the failing PCA Order a new PCA and see Replacing a PCA Replacing a PCA To replace a PCA 1 Turn off the client s power source to the failing PCA 2 Unplug the rack power cord from the PCA...

Page 41: ...ler v Two 10 100 1000 Mbps integrated Ethernet controllers v Eight front accessible disk bays supporting hot swappable disks Two are populated with 73 GB Ultra3 10K RPM disk drives These disk bays are...

Page 42: ...ront of the system and ending with an LED near the failing Field Replaceable Unit For more information about Client Replaceable Units including videos see http publib boulder ibm com eserver System at...

Page 43: ...sure of the DR550 SSAM Server Blue and orange Orange takes precedence over this color combination and the rules for a orange only touch point apply Attention It is important to adhere to the touch poi...

Page 44: ...n safely support this weight when removing the server unit from the system rack The IBM Systems Hardware Information Center is available for more information or to view available video clips that desc...

Page 45: ...ible using the Advanced System Management Interface ASMI or the control panel Extended control panel functions The extended control panel functions consist of two major groups v Functions 21 through 4...

Page 46: ...through the operating system is not a concurrent process Temporary and permanent firmware sides The service processor maintains two copies of the server firmware v One copy is considered the permanent...

Page 47: ...ww14 software ibm com webapp set2 firmware Service processor The service processor is an embedded controller running the service processor internal operating system The service processor operating sys...

Page 48: ...ed server or a logical partition In the case of a network boot SMS menus are provided to set up the network parameters and network adapter IP address 20 DR550 Version 4 5 Problem Determination and Ser...

Page 49: ...choice of SX or TX connections Note Copper Ethernet TX adapters are placed in slots 3 and 4 Optional Fibre Ethernet SX adapters are placed in slots 1 and 2 v Two integrated Ethernet ports used if ther...

Page 50: ...control button shield comes installed on the server to prevent the server from being turned off accidentally v Power on LED When this LED is lit and not flashing it indicates that the server is turned...

Page 51: ...it indicates that the drive is in use Hard disk drive status LED On some server models each hot swap hard disk drive has a status LED When this LED is lit it indicates that the drive has failed When t...

Page 52: ...ndicate that there is an active link connection on the 10BASE T 100BASE TX or 1000BASE TX interface for the Ethernet port Ethernet connectors Use either of these connectors to connect the server to a...

Page 53: ...cs Use light path diagnostics to diagnose system errors quickly See Light path diagnostics on page 39 for more information POST beep codes POST emits one beep to signal successful completion If POST d...

Page 54: ...ly In the Configuration Setup Utility program make sure that all PCI devices are enabled Disable option ROMs and integrated devices that are not needed and set the PCI device boot priority to ensure t...

Page 55: ...oops Make more space available on the hard disk The ServerGuide program will not start the operating system CD Make sure that the operating system CD is supported by the ServerGuide program See the Se...

Page 56: ...replaceable units FRU v If an action step is preceded by Trained service technician only that step must be performed only by a trained service technician Symptom Action The CD or DVD drive is not reco...

Page 57: ...during the hard disk drive diagnostic test Remove the hard disk drive that was being tested when the server stopped responding and run the diagnostic test again If the hard disk drive diagnostic test...

Page 58: ...evice driver If the reset continues to occur after the operating system starts the operating system might have a problem 3 If neither condition applies check the system event error log or BMC system e...

Page 59: ...s compatible with the server See http www ibm com servers eserver serverproven compat us for keyboard compatibility v The mouse or pointing device cable is securely connected to the server and the dev...

Page 60: ...have automatically disabled a memory bank when it detected a problem or a memory bank might have been manually disabled 2 Check the POST error log for error message 289 v If a DIMM was disabled by a s...

Page 61: ...own self tests If you suspect a problem with your monitor see the documentation that comes with the monitor for instructions for testing and adjusting the monitor v Follow the suggested actions in th...

Page 62: ...If this occurs and the Boot Fail Count option in the Start Options of the Configuration Setup Utility program is enabled you must restart the server three times to reset the configuration settings to...

Page 63: ...r Attention Moving a color monitor while it is turned on might cause screen discoloration Move the device and the monitor at least 305 mm 12 in apart and turn on the monitor Notes a To prevent diskett...

Page 64: ...instructions that came with the device and the device is installed correctly v You have not loosened any other installed devices or cables v You updated the configuration information in the Configura...

Page 65: ...work replace the operator information panel assembly e Press the reset button on the light path diagnostics panel to restart the server If the button does not work replace the operator information pan...

Page 66: ...nents are customer replaceable units CRU and which components are field replaceable units FRU v If an action step is preceded by Trained service technician only that step must be performed only by a t...

Page 67: ...urchase of the software Universal Serial Bus USB port problems v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved v See the parts lis...

Page 68: ...ng system is shut down Diagnosing problems using light path diagnostics LEDs in two locations on the server are available to help you diagnose problems that might occur during installation Use them in...

Page 69: ...ated 2 Replace the power supply CPU A microprocessor has failed Make sure that the failing microprocessor which is indicated by a lit LED on the system board is installed correctly VRM An error occurr...

Page 70: ...lf TEMP The system temperature has exceeded a threshold level A failing fan can cause the TEMP LED to be lit 1 Determine whether a fan has failed 2 Make sure that the room temperature is not too high...

Page 71: ...with DS4000 Storage Manager for DR550 on SSAM server Note You can launch SMClient from the IBM Director interface by right clicking on the DR550 Storage Controller object and selecting DR550 Configur...

Page 72: ...e replace the RAID controller Unsupported controller type For example a DS4700 FRU is inserted into a DR550 Storage Controller chassis Use the Storage Manager Client Subsystem Management window and Re...

Page 73: ...in the storage subsystem Replace the failed SFP module See the DS4200 Installation User s and Maintenance Guide for more information Battery unit fault Battery unit failure Verify the failure using DS...

Page 74: ...nt logs to isolate the faulty component Controller drive port bypass LED The enclosure speed was set to 4 Gbps but the SFP inserted in the controller drive SFP port does not operate at 4 Gbps Use the...

Page 75: ...re failure Replace the affected CRUs If this does not correct the problem replace the RAID controllers followed by the midplane Contact an IBM technical support representative Front panel Power supply...

Page 76: ...D management software Several CRUs Drive or drives failed Replace failed drive or drives FC cable failed Replace FC cable SFP failed Replace SFP RAID controller failure Replace RAID controller Unsuppo...

Page 77: ...1Y0679 7 Blank drive module 42D3315 8 Serial cable adapter RoHS 39M5942 9 SFP LC shortwave 4 Gbps 22R6443 10 LC wrap plug assembly and LC coupler 39M5914 11 Power cord jumper 39M5377 12 Fibre cable 2...

Page 78: ...50 DR550 Version 4 5 Problem Determination and Service Guide...

Page 79: ...njunction with the DS4000 Storage Manager for DR550 client to diagnose storage subsystem problems and component failures and to find solutions to problems that have definite symptoms Symptom to FRU in...

Page 80: ...00 Installation User s and Maintenance Guide and the FC loopback and female female LC connector Replace either input or output SFP modules or fibre channel cables as necessary Incorrect enclosure spee...

Page 81: ...r supply Drive CRUs Drive not certified Verify that the drive option or FRU CRU P N is listed in the support list for the appropriate DR550 Storage Controller storage subsystems Note In certain cases...

Page 82: ...as set to 4 Gbps but the SFP inserted in the ESM SFP port does not operate at 4 Gbps Use the Recovery Guru menu function in the Storage Manager Client Subsystem Management window to verify the problem...

Page 83: ...ge Controller storage subsystem in the same redundant drive channel pair Verify that all of the storage expansion enclosures and DR550 Storage Controller storage subsystem enclosure speeds are the sam...

Page 84: ...slowly flashing one per 2 seconds Drive CRUs The DS4000 was not powered on or all fibre channel connections between the DR550 Expansion Drawer and the DS4000 storage subsystem failed Perform one of th...

Page 85: ...drives Drive is not certified Check FRU P N certified for your DR550 Storage Controller Random errors Subsystem Midplane failure Have the midplane replaced Contact an IBM technical support representa...

Page 86: ...d DR2 23R2894 Finding controller storage expansion enclosure and drive information You can view a Storage Subsystem Profile to find controller enclosure and drive information for the DR550 Expansion D...

Page 87: ...res tab 6 Scroll through the list to find the Product ID for supported storage expansion enclosures as shown in Table 12 Table 12 Product ID for supported storage expansion enclosures compatible with...

Page 88: ...60 DR550 Version 4 5 Problem Determination and Service Guide...

Page 89: ...h and the first component in the network is less than 300 meter Twelve ports are populated with 4 gigabit shortwave transceivers and four ports are populated with 4 gigabit long wave transceivers when...

Page 90: ...de of the switch see Figure 11 on page 63 They include 8 Power Status green only to indicate a valid power supply to the system 9 System Status green amber to indicate the current system status 11 Eth...

Page 91: ...patterns and recommended actions Table 14 on page 64 Table 15 on page 65 and Table 16 on page 65 summarize LED location color and meaning of the LEDs on the switch as well as any recommended user res...

Page 92: ...owing are true v One or more environmental ranges are exceeded v Error log contains one or more port diagnostic error messages Complete the following steps 1 Check environmental conditions error log P...

Page 93: ...ble command See the Brocade Fabric OS Command Reference Manual for more information If all ports are slow flashing amber enable the switch using the switchEnable command Fast flashing amber on 1 4 sec...

Page 94: ...wave port 9 Enhanced Remote Mirror Unzoned Shortwave port 10 Connection to remote SAN switch Shortwave port 11 Unused Longwave port 12 Connection to remote SAN switch Longwave ports 13 14 and 15 Unuse...

Page 95: ...pportsave and gather the data for problem determination You can use Fabric Manager to save the supportshow command output as a text file Send the text file to your technical support contact for analys...

Page 96: ...68 DR550 Version 4 5 Problem Determination and Service Guide...

Page 97: ...0 system components SSAM server s File System Gateway s Storage Controller s SAN Switch es Switch characteristics The following sections describe the physical characteristics of the switch Ethernet sw...

Page 98: ...Ethernet adapter in slot 4 port 2 FC 4101 T5 SSAM Server 1 Eth1 t5 port FC 5502 T6 T7 Storage Controller 1 Controller A top Port 2 FC 5837 5838 T8 Storage Controller 1 Controller B bottom Port 1 FC 5...

Page 99: ...2 FC 5502 T6 SSAM Server 2 Ethernet adapter in slot 5 port 2 FC 5502 T7 Storage Controller 2 Controller A top Port 2 Expansion rack FC 5837 5838 T8 Storage Controller 2 Controller B bottom Port 1 Exp...

Page 100: ...ck by removing one screw from each end of the Ethernet switch and partially slide out the Ethernet switch 5 Ensure the short power cord that goes from the sheet metal bracket to the power connector on...

Page 101: ...n from which the failing Ethernet switch was removed 2 Secure the Ethernet switch to the rack with the screws that were previously removed when the failing Ethernet switch was removed 3 Reinsert all E...

Page 102: ...74 DR550 Version 4 5 Problem Determination and Service Guide...

Page 103: ...a encryption 128 bit Advanced Encryption Standard AES is now available for the Archive API Client as well as 56 bit Data Encryption Standard DES Data can now be encrypted using either method before tr...

Page 104: ...r information on customizing these settings System Storage Archive Manager database and logs For the DR550 Single and Dual Node configurations a logical volume for the SSAM database and a logical volu...

Page 105: ...is not accessible kill process dsmserv Requires restart of the SSAM server DR550 specific version of DS4000 Storage Manager The DR550 specific version of the DS4000 Storage Manager software hereafter...

Page 106: ...a lower cost of ownership and deliver new powerful information and services to customers partners and employees where and when needed It is comprised of two core repository products that are integrate...

Page 107: ...ommon Internet File System CIFS or Network File System NFS file system protocols The FSG interacts with the other DR550 components via the System Storage Archive Manager SSAM API As files are sent to...

Page 108: ...80 DR550 Version 4 5 Problem Determination and Service Guide...

Page 109: ...management server must use a proxy server to access the Internet you must configure the firewalls and proxy server to enable installation and operation of IBM Director Client For additional instructi...

Page 110: ...f all the components select Associations Archive Systems to see the components grouped under the DR550 object Separate DR550 objects will appear for each DR550 Version 4 5 or above that is visible to...

Page 111: ...cify a subnet 1 Select Options Discovery Preferences A new pop up window will appear 2 Select the Level 2 IBM Director Agents tab 3 Select the System Discovery IP radio button 4 Below Address Entries...

Page 112: ...t be resolved on some systems to enable this feature RedHat When the IBM Director is installed on RedHat systems it is necessary to modify some settings to successfully launch SMclient On the system w...

Page 113: ...yes 3 Save your change 4 Run SuSEconfig command 5 Reboot the IBM Director Console machine Running IBM Director 5 20 1 instead of 5 20 2 Archive Systems Management Interface recommends running IBM Dire...

Page 114: ...ore discovering the storage systems Linux 1 Open the opt ibm director data SmisAttributesBase properties file in a text editor 2 Find the line that starts with enabled_values 0 1 3 Insert 1814 FAStT b...

Page 115: ...ctor Agent on AIX is one of the listeners for diagnostic events besides the Service Focal Point on HMC as well as the Service Agent product Registering IBM Director Agent as an AIX diagnostics listene...

Page 116: ...ep CIM you should see something like the following DType CIM_DIAG1 DApp opt freeware cimom pegasus bin CIMDiagListener sh DType CIM_DIAG2 DApp opt freeware cimom pegasus bin CIMDiagListener sh 3 Check...

Page 117: ...imlistener conf v Uncomment or comment traceComponents LISTENER traceLevel 4 v Restart cimlistener 4 Duplicate error entries are not passed on to Director To find out if the error has already been rep...

Page 118: ...90 DR550 Version 4 5 Problem Determination and Service Guide...

Page 119: ...pin Note This action will release the door from the hinges 3 Grasp the door firmly with both hands and pull it away from the hinges Replacing the DR1 front door To replace the DR1 front door follow t...

Page 120: ...osition 3 Close the left rear door it will be necessary to squeeze the blue colored slide bars together during this action to completely close the door 4 Grasp the right rear door firmly with both han...

Page 121: ...he upper door hinge pins Note This action will release the door from the hinges 3 Using both hands firmly grasp the door and remove it from the hinges Replacing the DR2 front door To replace the DR2 f...

Page 122: ...er hinges 2 Close the door and lock it using the DR2 door key Removing a DR2 side panel To remove a DR2 side panel follow these steps 1 At the rear of the rack unlock the door using the DR2 door key a...

Page 123: ...es for the DR550 SSAM Server component DR550 SSAM Server RAID Disk Controller rechargeable battery maintenance Attention v This procedure should only be performed if directed from an isolation procedu...

Page 124: ...eable cache battery pack The possible values for this field are v No battery warning error No warning or error condition currently exists v Warning condition A warning condition currently exists and a...

Page 125: ...I O adapter and 575B Auxiliary Cache adapter is contained in a single battery FRU that is physically located on the 575B Auxiliary Cache adapter The functions of forcing a battery pack error and start...

Page 126: ...ollowing Procedure for non Concurrently Maintainable Battery Packs Use the following procedure for replacing non concurrently maintainable battery packs 1 Determine that it is safe to replace the cach...

Page 127: ...mware in the upper right corner below the copyright statement for example SF230_156 Depending on your situation you might need to update the system to the latest server firmware code level after you r...

Page 128: ...u may have set using operating system commands Record the current bootlist order which can be found in the SMS menus Remove the service processor assembly or time of day battery To remove the service...

Page 129: ...ging your hardware v When using a wrist strap follow all electrical safety procedures A wrist strap is for static control It does not increase or decrease your risk of receiving electric shock when us...

Page 130: ...d to remove and replace the time of day battery from the server Use the procedure in this section to perform this task Note This battery is used within the DR550 SSAM Server for models DR1 and DR2 To...

Page 131: ...on call 1 800 426 4333 Have the IBM part number for the battery unit available when you call C003 4 Before replacing the battery ensure that positive side of the battery is facing up 5 Insert the batt...

Page 132: ...m frame 3 While holding the service processor assembly by the handles carefully push the assembly into place B Note Ensure that the two pins on the flange of the service processor assembly align with...

Page 133: ...et TX Dual Port Adapter slot 5 and 6 v Feature Code 3551 Host Ethernet TX Dual Port Adapter slot 3 v Feature Code 3560 LVD SCSI adapter for tape or optical storage slot 3 v Dual port Fibre Channel Ada...

Page 134: ...e peripheral devices and the server Note When you restart the server you will be given the opportunity to import the existing RAID configuration to the new ServeRAID SAS controller Removing the system...

Page 135: ...battery complete the following steps 1 Review Safety notices on page xi and the safety information and installation guidelines in the IBM System x3650 Type 7979 and 1914 Problem Determination and Serv...

Page 136: ...ion that you must consider when replacing the battery in the server v After you replace the battery you must reconfigure the server and reset the system date and time v To avoid possible danger read a...

Page 137: ...ard the housing until it snaps into place 3 Reinstall any adapters that you removed 4 Reconnect the internal cables that you disconnected 5 Make sure that the riser card assembly is fully seated in th...

Page 138: ...g procedure to replace a controller in a DR550 Storage Controller Storage Subsystem Each controller has a unique hardware Ethernet address which is printed on a label on the front 1 Use the DS4000 Sto...

Page 139: ...all attached interface cables from the failed controller including the SFP modules Ensure that you label each cable so that you can reconnect them correctly to the new controller Use the following pr...

Page 140: ...hands when releasing the controller levers Figure 36 shows the controller sliding from the storage subsystem chassis 10 If the new controller does not have the cache battery backup unit already insta...

Page 141: ...remaining Recovery Guru procedures for controller replacement if needed 14 Check the LEDs on the new controller to verify that the controller is fully operational 15 Remove the antistatic protection...

Page 142: ...nit that maintains data in the cache memory for three days without power to the unit Use the following procedure if the DS4000 Storage Manager for DR550 client instructs you to replace the battery uni...

Page 143: ...the black colored battery pull handle 4 to unlatch the battery from the DR550 Storage Controller chassis and slowly pull the battery unit from the controller chassis using the black handle as shown i...

Page 144: ...chassis Make sure the new battery unit is inserted in the correct orientation in the battery unit bay Press the battery unit fully into the bay until it clicks into place Do not force fit The battery...

Page 145: ...2 Gbps SFP that is plugged into a 4 Gbps capable port will limit the speed of that port to a maximum of 2 Gbps v Handle and install fiber optic cables properly to avoid degraded performance or loss of...

Page 146: ...from the power supply and fan units of the DR550 Storage Controller 3 Label the fibre channel cables that are attached to the rear of the controllers Labeling the cables simplifies the re cabling proc...

Page 147: ...the new front cage frame with the midplane Save the packaging materials in case you need to return it 12 Insert the new midplane by aligning it with the storage subsystem front opening and slowly slid...

Page 148: ...EXP420 CRUs Use the following procedures to replace the customer replaceable units CRUs in the EXP420 after the EXP420 is installed successfully in a rack Replacing an ESM Complete the following steps...

Page 149: ...step 1 on page 120 and step 2 to replace the second ESM Replacing a power supply and fan unit CAUTION The power control button on the device and the power switch on the power supply do not turn off th...

Page 150: ...notches and power supply and fan unit fits snugly into the slot push the lever upward or downward 90 depending on whether the power supply fan is inserted in the left or right bay to fully latch it in...

Page 151: ...the maximum operating speed of the fibre channel port in which the SFP is installed For example a 2 Gbps SFP that is plugged into a 4 Gbps capable port will limit the speed of that port to a maximum o...

Page 152: ...50 Storage Controller is turned off before any attached storage expansion enclosures 2 Power off the DR550 Expansion Drawer that will have its midplane replaced 3 Remove the power cords from the power...

Page 153: ...four front cage frame screws on the midplane as shown in Figure 45 11 Grab the blue handle in the center of the front cage frame and pull it outward to slide the front cage frame out approximately two...

Page 154: ...llation Attention After you remove an EV DDM CRU wait 70 seconds before replacing or reseating it to allow it to properly spin down Failure to do so may cause undesired events 1 Lift up on the handle...

Page 155: ...compressed into a single file using zip or tar depending upon the platform Additionally the user can open a remote session to the server and compress the files using tar cvf output file list of files...

Page 156: ...ffloaded are in a directory where the user ibmce has read access for example home ibmce Multiple files can be combined put in one file with tar cvf output file list of files to be combined The combine...

Page 157: ...agrams DR2 cabling single node Figure 47 DR2 Fiber Cabling Single Node from one Storage Controller to one SAN Switch to one SSAM Server and from one Storage Controller to one SSAM Server without mirro...

Page 158: ...Figure 48 DR2 Fiber Cabling Single Node from two Storage Controllers to one SAN Switch to one SSAM Server without mirroring 130 DR550 Version 4 5 Problem Determination and Service Guide...

Page 159: ...Figure 49 DR2 Fiber Cabling Single Node from one Storage Controller to one SAN Switch to one SSAM Server with SW mirroring Appendix A DR1 and DR2 cabling diagrams 131...

Page 160: ...Figure 50 DR2 Fiber Cabling Single Node from one Storage Controller to one SAN Switch one to one SSAM Server with LW mirroring 132 DR550 Version 4 5 Problem Determination and Service Guide...

Page 161: ...Figure 51 DR2 Ethernet Cabling Single Node one or two File System Gateways to SSAM Server Appendix A DR1 and DR2 cabling diagrams 133...

Page 162: ...2 Ethernet Cabling Single node one SSAM Server to two Storage Controllers Figure 53 DR2 Ethernet Cabling Single node One SAN Switch to Ethernet Switch 134 DR550 Version 4 5 Problem Determination and S...

Page 163: ...R2 KVM Switch Cabling Single Node Two File System Gateways and one SSAM Server Figure 55 DR2 KVM Switch Cabling Single Node One File System Gateway and one SSAM server Appendix A DR1 and DR2 cabling d...

Page 164: ...Figure 56 DR2 KVM Switch Cabling Single Node one SSAM Server with KVM Switch and one SSAM Server without KVM Switch 136 DR550 Version 4 5 Problem Determination and Service Guide...

Page 165: ...DR2 cabling dual node Figure 57 DR2 Fiber Cabling Dual Node from two Storage Controllers to two SAN Switches to two SSAM Servers without mirroring Appendix A DR1 and DR2 cabling diagrams 137...

Page 166: ...roller to two SAN Switches to two SSAM servers with software mirroring Figure 59 DR2 Fiber Cabling Dual Node from one Storage Controller to two SAN Switches to two SSAM servers without LW mirroring 13...

Page 167: ...Figure 60 DR2 Ethernet Cabling Dual Node two File System Gateways to two SSAM servers Appendix A DR1 and DR2 cabling diagrams 139...

Page 168: ...Ethernet Cabling Dual node two SSAM Servers to two Storage Controllers Figure 62 DR2 Ethernet Cabling Dual node Two SAN Switches to Ethernet Switches 140 DR550 Version 4 5 Problem Determination and S...

Page 169: ...VM Switch Cabling Dual Node Two File System Gateways and two SSAM Servers Figure 64 DR2 KVM Switch Cabling Dual Node two SSAM Servers Figure 65 DR2 Fiber Cabling Storage Controller 1 to Expansion Draw...

Page 170: ...Figure 66 DR2 Fiber Cabling Storage Controller 1 to Expansion Drawers 1 1 and 2 1 142 DR550 Version 4 5 Problem Determination and Service Guide...

Page 171: ...Figure 67 DR2 Fiber Cabling Storage Controller 1 to Expansion Drawers 1 1 2 1 and 3 1 Appendix A DR1 and DR2 cabling diagrams 143...

Page 172: ...ling Storage Controller 1 to Expansion Drawers 1 1 2 1 3 1 and 4 1 Figure 69 DR2 Fiber Cabling Storage Controller 1 to Expansion Drawers 1 1 2 1 3 1 4 1 and 5 1 144 DR550 Version 4 5 Problem Determina...

Page 173: ...70 DR2 Fiber Cabling Storage Controller 1 to Expansion Drawers 1 1 2 1 3 1 4 1 5 1 and 6 1 Figure 71 DR2 Fiber Cabling Storage Controller 2 to Expansion Drawer 1 2 Appendix A DR1 and DR2 cabling diagr...

Page 174: ...iber Cabling Storage Controller 2 to Expansion Drawers 1 2 and 2 2 Figure 73 DR2 Fiber Cabling Storage Controller 2 to Expansion Drawers 1 2 2 2 and 3 2 146 DR550 Version 4 5 Problem Determination and...

Page 175: ...Figure 74 DR2 Fiber Cabling Storage Controller 2 to Expansion Drawers 1 2 2 2 3 2 and 4 2 Appendix A DR1 and DR2 cabling diagrams 147...

Page 176: ...Figure 75 DR2 Fiber Cabling Storage Controller 2 to Expansion Drawers 1 2 2 2 3 2 4 2 and 5 2 148 DR550 Version 4 5 Problem Determination and Service Guide...

Page 177: ...Figure 76 DR2 Fiber Cabling Storage Controller 2 to Expansion Drawers 1 2 2 2 3 2 4 2 5 2 and 6 2 Appendix A DR1 and DR2 cabling diagrams 149...

Page 178: ...DR2 power cabling Figure 77 DR2 power cabling primary rack 150 DR550 Version 4 5 Problem Determination and Service Guide...

Page 179: ...Figure 78 DR2 power cabling primary rack and expansion rack Appendix A DR1 and DR2 cabling diagrams 151...

Page 180: ...Figure 79 DR2 power cabling expansion rack 152 DR550 Version 4 5 Problem Determination and Service Guide...

Page 181: ...R1 cabling Figure 80 DR1 Ethernet cabling SSAM Server 1 to Storage Controller 1 Figure 81 DR1 Ethernet cabling File System Gateway 1 to File System Gateway 2 Appendix A DR1 and DR2 cabling diagrams 15...

Page 182: ...2 DR1 Fiber Cabling Storage Controller 1 to Expansion drawer 1 1 Figure 83 DR1 Fiber Cabling Storage Controller 1 to Expansion drawer 1 1 and 2 1 154 DR550 Version 4 5 Problem Determination and Servic...

Page 183: ...Figure 84 DR1 Fiber Cabling SSAM Server to Storage Controller Figure 85 DR1 KVM Switch Cabling with two File System Gateways and SSAM Server Appendix A DR1 and DR2 cabling diagrams 155...

Page 184: ...gure 86 DR1 KVM Switch Cabling with one File System Gateway and SSAM server Figure 87 DR1 Display Keyboard Mouse Cabling without KVM switch 156 DR550 Version 4 5 Problem Determination and Service Guid...

Page 185: ...DR1 power cabling Figure 88 DR1 Power Cabling Appendix A DR1 and DR2 cabling diagrams 157...

Page 186: ...Figure 89 DR1 Power Cabling 158 DR550 Version 4 5 Problem Determination and Service Guide...

Page 187: ...nd File System Gateway layout graphics for adapter placement and port assignment and other unit graphics Figure 90 File System Gateway adapter port identification usage Appendix A DR1 and DR2 cabling...

Page 188: ...Figure 91 SSAM Server adapter port identification usage Figure 92 Ethernet switch port identification used unused and reserved ports 160 DR550 Version 4 5 Problem Determination and Service Guide...

Page 189: ...Figure 93 SAN switch port identification Figure 94 KVM switch port identification Appendix A DR1 and DR2 cabling diagrams 161...

Page 190: ...Figure 95 Storage Controller port identification 162 DR550 Version 4 5 Problem Determination and Service Guide...

Page 191: ...Figure 96 Expansion Drawer port identification Appendix A DR1 and DR2 cabling diagrams 163...

Page 192: ...Figure 97 Power Control Assembly PCA port identification 164 DR550 Version 4 5 Problem Determination and Service Guide...

Page 193: ...directory of the program file dapismp See Figure 98 for an example The TCPSERVERADDRESS is the address of the DR550 The statement ENABLEARCHIVERETENTIONPROTECTION yes is required The parameters Trace...

Page 194: ...Password 7 Utilities Deletes Updates Logevent SetAccess RetentionEvent 8 Set preferences envSetUp 9 Exit to system 10 Restore Retrieve Without Offset Prompt Enter selection 0 Node name hausteintp Own...

Page 195: ...ace usr Highlevel tivoli tsm client api bin samples Lowlevel dapismp Object Type D F F Object Owner Name Object already compressed Y N n Wait for mount Y N n File size 130000 Number of files 1 Seed st...

Page 196: ...m expire time hhmm To expire date mmddyyyy To expire time hhmm Archive description paul Show detailed output Y N y On Retrieve Wait for mount Y N n Are the above responses correct y n q y Item 1 usr t...

Page 197: ...selection 7 Choose one of the following actions 0 Access Delete 1 Backup Delete 2 Archive Delete 3 Filespace Delete 4 Backup Update 5 Filespace Update 6 Log Event 7 Set Access 8 Archive Update 9 Quit...

Page 198: ...y n q y Mgmt Class 1 Name DRP_MGM_CLASS Description Management Class for DRP Backup CG Name Frequency 0 Ver Data Exists 0 Ver Data Deleted 0 Retain Extra Ver 0 Retain Only Ver 0 Copy Serialization Un...

Page 199: ...x listed below 2 The LUN sizes listed in the below tables are raw sizes and AIX overhead can take up to 10 of the DR550 Storage Controller capacity Logical Volume configuration for DR1 Table 25 LV con...

Page 200: ...gslvm tsmDbM tsmLogM SSAMvgM 2000 GB 1 3 hdisk3 TSMStg 2000 GB 1 4 hdisk4 TSMStg 390 GB 1 5 hdisk5 TSMStg 2000 GB 2 6 hdisk6 TSMStg 2000 GB 2 7 hdisk7 TSMStg 1250 GB 2 8 hdisk8 TSMStg 2000 GB 3 9 hdis...

Page 201: ...g 2000 GB 2 6 hdisk6 TSMStg 2000 GB 2 7 hdisk7 TSMStg 1250 GB 2 8 hdisk8 TSMStg 2000 GB 3 9 hdisk9 TSMStg 2000 GB 3 10 hdisk10 TSMStg 500 GB 3 11 hdisk11 TSMStg 2000 GB 4 12 hdisk12 TSMStg 2000 GB 4 1...

Page 202: ...hdisk1 tsmappslv tsmdblv tsmlogslv tsmbackuplv tsm tsmDb tsmLog tsmdbbkup SSAMvg Table 33 LV configuration for 6 TB systems single and dual node LUN Size Array ID LUN ID Hdisk on AIX Logical Volume F...

Page 203: ...hdisk6 TSMStg 2000 GB 2 7 hdisk7 TSMStg 500 GB 2 8 hdisk8 TSMStg 2000 GB 3 9 hdisk9 TSMStg 2000 GB 3 10 hdisk10 TSMStg 500 GB 3 11 hdisk11 TSMStg Table 36 LV configuration for 24 TB systems single and...

Page 204: ...500 GB 4 14 hdisk14 TSMStg 2000 GB 5 15 hdisk15 TSMStg 2000 GB 5 16 hdisk16 TSMStg 500 GB 5 17 hdisk17 TSMStg Table 38 LV configuration for 36 TB systems single and dual node LUN Size Array ID LUN ID...

Page 205: ...bbkup TSMDbBkup 500 GB 1 5 hdisk6 TSMStg 823 GB 1 6 hdisk7 TSMStg 1530 GB 2 7 hdisk8 TSMStg Table 40 LV configuration for 12 TB systems single and dual node LUN Size Array ID LUN ID Hdisk on AIX Logic...

Page 206: ...3 tsmdblv tsmlogslv tsmDb tsmLog TSMDbLogs 175 GB 3 3 hdisk4 tsmdblvm tsmlogslvm tsmDbM tsmLogM TSMDbLogsMirr 320 GB 2 4 hdisk5 tsmdbbkuplv tsmdbbkup TSMDbBkup 500 GB 1 5 hdisk6 TSMStg 2000 GB 1 6 hdi...

Page 207: ...Size Array ID LUN ID Hdisk on AIX Logical Volume File System VG Name 2 GB 1 1 hdisk2 tsmappslv tsm TSMApps 225 GB 1 2 hdisk3 tsmdblv tsmlogslv tsmDb tsmLog TSMDbLogs 225 GB 3 3 hdisk4 tsmdblvm tsmlogs...

Page 208: ...disk16 TSMStg 2000 GB 5 16 hdisk17 TSMStg 2000 GB 5 17 hdisk18 TSMStg 500 GB 5 18 hdisk19 TSMStg 2000 GB 6 19 hdisk20 TSMStg 2000 GB 6 20 hdisk21 TSMStg 1250 GB 6 21 hdisk22 TSMStg 2000 GB 7 22 hdisk2...

Page 209: ...SMStg Table 47 LV configuration for 60 TB systems single and dual node LUN Size Array ID LUN ID Hdisk on AIX Logical Volume File System VG Name 2 GB 1 1 hdisk2 tsmappslv tsm TSMApps 225 GB 1 2 hdisk3...

Page 210: ...LUN ID Hdisk on AIX Logical Volume File System VG Name 2 GB 1 1 hdisk2 tsmappslv tsm TSMApps 225 GB 1 2 hdisk3 tsmdblv tsmlogslv tsmDb tsmLog TSMDbLogs 225 GB 3 3 hdisk4 tsmdblvm tsmlogslvm tsmDbM tsm...

Page 211: ...0 TSMStg Table 49 LV configuration for 84 TB systems single and dual node LUN Size Array ID LUN ID Hdisk on AIX Logical Volume File System VG Name 2 GB 1 1 hdisk2 tsmappslv tsm TSMApps 225 GB 1 2 hdis...

Page 212: ...000 GB 12 37 hdisk38 TSMStg 2000 GB 12 38 hdisk39 TSMStg 1250 GB 12 39 hdisk40 TSMStg 2000 GB 13 40 hdisk41 TSMStg 2000 GB 13 41 hdisk42 TSMStg 500 GB 13 42 hdisk43 TSMStg 2000 GB 14 43 hdisk44 TSMStg...

Page 213: ...000 GB 8 26 hdisk27 TSMStg 1250 GB 8 27 hdisk28 TSMStg 2000 GB 9 28 hdisk29 TSMStg 2000 GB 9 29 hdisk30 TSMStg 500 GB 9 30 hdisk31 TSMStg 2000 GB 10 31 hdisk32 TSMStg 2000 GB 10 32 hdisk33 TSMStg 1250...

Page 214: ...TSMStg 2000 GB 2 9 hdisk10 TSMStg 830 GB 2 10 hdisk11 TSMStg 2000 GB 3 11 hdisk12 TSMStg 1825 GB 3 12 hdisk13 TSMStg 2000 GB 4 13 hdisk14 TSMStg 2000 GB 4 14 hdisk15 TSMStg 1250 GB 4 15 hdisk16 TSMStg...

Page 215: ...k53 TSMStg 2000 GB 17 53 hdisk54 TSMStg 500 GB 17 54 hdisk55 TSMStg 2000 GB 18 55 hdisk56 TSMStg 2000 GB 18 56 hdisk57 TSMStg 1250 GB 18 57 hdisk58 TSMStg Table 52 LV configuration for 120 TB systems...

Page 216: ...9 30 hdisk31 TSMStg 2000 GB 10 31 hdisk32 TSMStg 2000 GB 10 32 hdisk33 TSMStg 1250 GB 10 33 hdisk34 TSMStg 2000 GB 11 34 hdisk35 TSMStg 2000 GB 11 35 hdisk36 TSMStg 500 GB 11 36 hdisk37 TSMStg 2000 GB...

Page 217: ...tsmDb tsmLog TSMDbLogs 225 GB 3 3 hdisk4 tsmdblvm tsmlogslvm tsmDbM tsmLogM TSMDbLogsMirr 420 GB 2 4 hdisk5 tsmdbbkuplv tsmdbbkup TSMDbBkup 500 GB 1 5 hdisk6 TSMStg 2000 GB 1 6 hdisk7 TSMStg 1773 GB 1...

Page 218: ...00 GB 14 43 hdisk44 TSMStg 2000 GB 14 44 hdisk45 TSMStg 1250 GB 14 45 hdisk46 TSMStg 2000 GB 15 46 hdisk47 TSMStg 2000 GB 15 47 hdisk48 TSMStg 500 GB 15 48 hdisk49 TSMStg 2000 GB 16 49 hdisk50 TSMStg...

Page 219: ...7 hdisk8 TSMStg 2000 GB 2 8 hdisk9 TSMStg 2000 GB 2 9 hdisk10 TSMStg 830 GB 2 10 hdisk11 TSMStg 2000 GB 3 11 hdisk12 TSMStg 1825 GB 3 12 hdisk13 TSMStg 2000 GB 4 13 hdisk14 TSMStg 2000 GB 4 14 hdisk1...

Page 220: ...000 GB 16 50 hdisk51 TSMStg 1250 GB 16 51 hdisk52 TSMStg 2000 GB 17 52 hdisk53 TSMStg 2000 GB 17 53 hdisk54 TSMStg 500 GB 17 54 hdisk55 TSMStg 2000 GB 18 55 hdisk56 TSMStg 2000 GB 18 56 hdisk57 TSMStg...

Page 221: ...hdisk9 TSMStg 2000 GB 2 9 hdisk10 TSMStg 830 GB 2 10 hdisk11 TSMStg 2000 GB 3 11 hdisk12 TSMStg 1825 GB 3 12 hdisk13 TSMStg 2000 GB 4 13 hdisk14 TSMStg 2000 GB 4 14 hdisk15 TSMStg 1250 GB 4 15 hdisk16...

Page 222: ...250 GB 16 51 hdisk52 TSMStg 2000 GB 17 52 hdisk53 TSMStg 2000 GB 17 53 hdisk54 TSMStg 500 GB 17 54 hdisk55 TSMStg 2000 GB 18 55 hdisk56 TSMStg 2000 GB 18 56 hdisk57 TSMStg 1250 GB 18 57 hdisk58 TSMStg...

Page 223: ...Mirr 420 GB 2 4 hdisk5 tsmdbbkuplv tsmdbbkup TSMDbBkup 500 GB 1 5 hdisk6 TSMStg 2000 GB 1 6 hdisk7 TSMStg 1773 GB 1 7 hdisk8 TSMStg 2000 GB 2 8 hdisk9 TSMStg 2000 GB 2 9 hdisk10 TSMStg 830 GB 2 10 hdi...

Page 224: ...2000 GB 15 46 hdisk47 TSMStg 2000 GB 15 47 hdisk48 TSMStg 500 GB 15 48 hdisk49 TSMStg 2000 GB 16 49 hdisk50 TSMStg 2000 GB 16 50 hdisk51 TSMStg 1250 GB 16 51 hdisk52 TSMStg 2000 GB 17 52 hdisk53 TSMSt...

Page 225: ...or DR2 RAID 6 Table 57 LV configuration for 6 TB systems single and dual node LUN Size Array ID LUN ID Hdisk on AIX Logical Volume File System VG Name 2 GB 1 1 hdisk2 tsmappslv tsm TSMApps 175 GB 1 2...

Page 226: ...TSMStg 1823 GB 1 7 hdisk8 TSMStg 2000 GB 2 8 hdisk9 TSMStg 2000 GB 2 9 hdisk10 TSMStg 180 GB 2 10 hdisk11 TSMStg 2000 GB 3 11 hdisk12 TSMStg 2000 GB 3 12 hdisk13 TSMStg 325 GB 3 13 hdisk14 TSMStg Tabl...

Page 227: ...2000 GB 2 8 hdisk9 TSMStg 2000 GB 2 9 hdisk10 TSMStg 80 GB 2 10 hdisk11 TSMStg 2000 GB 3 11 hdisk12 TSMStg 2000 GB 3 12 hdisk13 TSMStg 275 GB 3 13 hdisk14 TSMStg 2000 GB 4 14 hdisk15 TSMStg 2000 GB 4...

Page 228: ...lume File System VG Name 2 GB 1 1 hdisk2 tsmappslv tsm TSMApps 325 GB 1 2 hdisk3 tsmdblv tsmlogslv tsmDb tsmLog TSMDbLogs 325 GB 3 3 hdisk4 tsmdblvm tsmlogslvm tsmDbM tsmLogM TSMDbLogsMirr 620 GB 2 4...

Page 229: ...tg 2000 GB 3 10 hdisk11 TSMStg 2000 GB 3 11 hdisk12 TSMStg 175 GB 3 12 hdisk13 TSMStg 2000 GB 4 13 hdisk14 TSMStg 2000 GB 4 14 hdisk15 TSMStg 500 GB 4 15 hdisk16 TSMStg 2000 GB 5 16 hdisk17 TSMStg 200...

Page 230: ...tg 500 GB 6 21 hdisk22 TSMStg 2000 GB 7 22 hdisk23 TSMStg 2000 GB 7 23 hdisk24 TSMStg 500 GB 7 24 hdisk25 TSMStg 2000 GB 8 25 hdisk26 TSMStg 2000 GB 8 26 hdisk27 TSMStg 500 GB 8 27 hdisk28 TSMStg 2000...

Page 231: ...MStg 500 GB 7 24 hdisk25 TSMStg 2000 GB 8 25 hdisk26 TSMStg 2000 GB 8 26 hdisk27 TSMStg 500 GB 8 27 hdisk28 TSMStg 2000 GB 9 28 hdisk29 TSMStg 2000 GB 9 29 hdisk30 TSMStg 500 GB 9 30 hdisk31 TSMStg 20...

Page 232: ...MStg 2000 GB 6 19 hdisk20 TSMStg 2000 GB 6 20 hdisk21 TSMStg 500 GB 6 21 hdisk22 TSMStg 2000 GB 7 22 hdisk23 TSMStg 2000 GB 7 23 hdisk24 TSMStg 500 GB 7 24 hdisk25 TSMStg 2000 GB 8 25 hdisk26 TSMStg 2...

Page 233: ...1 7 hdisk8 TSMStg 2000 GB 2 8 hdisk9 TSMStg 1630 GB 2 9 hdisk10 TSMStg 2000 GB 3 10 hdisk11 TSMStg 2000 GB 3 11 hdisk12 TSMStg 75 GB 3 12 hdisk13 TSMStg 2000 GB 4 13 hdisk14 TSMStg 2000 GB 4 14 hdisk1...

Page 234: ...TSMStg Table 69 LV configuration for 108 TB systems single and dual node LUN Size Array ID LUN ID Hdisk on AIX Logical Volume File System VG Name 2 GB 1 1 hdisk2 tsmappslv tsm TSMApps 425 GB 1 2 hdisk...

Page 235: ...2000 GB 11 34 hdisk35 TSMStg 2000 GB 11 35 hdisk36 TSMStg 500 GB 11 36 hdisk37 TSMStg 2000 GB 12 37 hdisk38 TSMStg 2000 GB 12 38 hdisk39 TSMStg 500 GB 12 39 hdisk40 TSMStg 2000 GB 13 40 hdisk41 TSMStg...

Page 236: ...hdisk14 TSMStg 2000 GB 4 14 hdisk15 TSMStg 500 GB 4 15 hdisk16 TSMStg 2000 GB 5 16 hdisk17 TSMStg 2000 GB 5 17 hdisk18 TSMStg 500 GB 5 18 hdisk19 TSMStg 2000 GB 6 19 hdisk20 TSMStg 2000 GB 6 20 hdisk...

Page 237: ...6 TSMStg 2000 GB 18 56 hdisk57 TSMStg 500 GB 18 57 hdisk58 TSMStg 2000 GB 19 58 hdisk59 TSMStg 2000 GB 19 59 hdisk60 TSMStg 500 GB 19 60 hdisk61 TSMStg 2000 GB 20 61 hdisk62 TSMStg 2000 GB 20 62 hdisk...

Page 238: ...B 8 27 hdisk28 TSMStg 2000 GB 9 28 hdisk29 TSMStg 2000 GB 9 29 hdisk30 TSMStg 500 GB 9 30 hdisk31 TSMStg 2000 GB 10 31 hdisk32 TSMStg 2000 GB 10 32 hdisk33 TSMStg 500 GB 10 33 hdisk34 TSMStg 2000 GB 1...

Page 239: ...disk69 TSMStg 500 GB 22 69 hdisk70 TSMStg Table 72 LV configuration for 144 TB systems single and dual node LUN Size Array ID LUN ID Hdisk on AIX Logical Volume File System VG Name 2 GB 1 1 hdisk2 tsm...

Page 240: ...B 11 34 hdisk35 TSMStg 2000 GB 11 35 hdisk36 TSMStg 500 GB 11 36 hdisk37 TSMStg 2000 GB 12 37 hdisk38 TSMStg 2000 GB 12 38 hdisk39 TSMStg 500 GB 12 39 hdisk40 TSMStg 2000 GB 13 40 hdisk41 TSMStg 2000...

Page 241: ...isk76 TSMStg Table 73 LV configuration for 156 TB systems single and dual node LUN Size Array ID LUN ID Hdisk on AIX Logical Volume File System VG Name 2 GB 1 1 hdisk2 tsmappslv tsm TSMApps 425 GB 1 2...

Page 242: ...GB 11 35 hdisk36 TSMStg 500 GB 11 36 hdisk37 TSMStg 2000 GB 12 37 hdisk38 TSMStg 2000 GB 12 38 hdisk39 TSMStg 500 GB 12 39 hdisk40 TSMStg 2000 GB 13 40 hdisk41 TSMStg 2000 GB 13 41 hdisk42 TSMStg 500...

Page 243: ...k77 TSMStg 2000 GB 25 77 hdisk78 TSMStg 500 GB 25 78 hdisk79 TSMStg 2000 GB 26 79 hdisk80 TSMStg 2000 GB 26 80 hdisk81 TSMStg 500 GB 26 81 hdisk82 TSMStg Table 74 LV configuration for 172 TB systems s...

Page 244: ...9 30 hdisk31 TSMStg 2000 GB 10 31 hdisk32 TSMStg 2000 GB 10 32 hdisk33 TSMStg 500 GB 10 33 hdisk34 TSMStg 2000 GB 11 34 hdisk35 TSMStg 2000 GB 11 35 hdisk36 TSMStg 500 GB 11 36 hdisk37 TSMStg 2000 GB...

Page 245: ...3 71 hdisk72 TSMStg 500 GB 23 72 hdisk73 TSMStg 2000 GB 24 73 hdisk74 TSMStg 2000 GB 24 74 hdisk75 TSMStg 500 GB 24 75 hdisk76 TSMStg 2000 GB 25 76 hdisk77 TSMStg 2000 GB 25 77 hdisk78 TSMStg 500 GB 2...

Page 246: ...218 DR550 Version 4 5 Problem Determination and Service Guide...

Page 247: ...country or send inquiries in writing to IBM World Trade Asia Corporation Licensing 2 31 Roppongi 3 chome Minato ku Tokyo 106 0032 Japan The following paragraph does not apply to the United Kingdom or...

Page 248: ...ServerGuide System p System Storage System x Tivoli TotalStorage Microsoft Windows and Windows NT are registered trademarks of Microsoft Corporation in the United States other countries or both Intel...

Page 249: ...Class A Emission Compliance Statement This Class A digital apparatus complies with Canadian ICES 003 Avis de conformit la r glementation d Industrie Canada Cet appareil num rique de la classe A est c...

Page 250: ...e Empfehlung der IBM gesteckt eingebaut werden EN 55022 Klasse A Ger te m ssen mit folgendem Warnhinweis versehen werden Warnung Dieses ist eine Einrichtung der Klasse A Diese Einrichtung kann im Wohn...

Page 251: ...ublic of China Class A Electronic Emission Statement Taiwanese Class A warning statement Japanese Voluntary Control Council for Interference VCCI statement Korean Class A Electronic Emission Statement...

Page 252: ...224 DR550 Version 4 5 Problem Determination and Service Guide...

Page 253: ...33 monitor 33 mouse USB 30 optional devices 36 pointing device USB 30 power 37 serial port 38 software 39 USB port 39 ESM replacing 120 Ethernet activity LED 24 connector 24 link status LED 24 system...

Page 254: ...midplane 118 124 SFP module 116 122 resources Web sites xxii S safety electrical xi frame installation xii frame relocation xiii inspections xiii laser xi rack xii safety inspection external machine c...

Page 255: ...on about products and prices please contact your IBM branch office your IBM business partner or your authorized remarketer When you send comments to IBM you grant IBM a nonexclusive right to use or di...

Page 256: ...opment Department GZW 9000 South Rita Road Tucson Arizona USA 85744 0001 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 257: ......

Page 258: ...Printed in USA GA32 0576 00...

Reviews: