000
The test passed.
195
The
Esc
key was pressed to abort the test.
197
This is a warning error and may not indicate a hardware failure.
For all error codes, replace/follow the FRU/Action indicated.
Error Code/Symptom
FRU/Action
001-XXX-000
(Failed core tests)
1.
System Board
001-XXX-001
(Failed core tests)
1.
System Board
001-250-000
(Failed System Board ECC)
1.
System Board
001-250-001
(Failed Processor Board ECC)
1.
System Board
005-XXX-000
(Failed Video test)
1.
Video adapter (if installed)
2.
System Board
011-XXX-000
(Failed COM1 Serial Port test)
1.
Check loopback plug connected to externalized serial port
2.
Check cable from externalized port to system board. Should
connect to Serial Port A on the system board (J52).
3.
System Board
011-XXX-001
(Failed COM2 Serial Port test)
1.
Check loopback plug connected to externalized serial port
2.
Check cable from externalized port to system board. Should
connect to Serial Port B on the system board (J51).
3.
System Board
014-XXX-000
(Failed Parallel Port test)
1.
System Board
015-XXX-001
(USB interface not found,
board damaged)
1.
System Board
015-XXX-198
(USB device connected during
USB test)
1.
Remove USB devices from USB1 and USB2.
2.
System Board
020-XXX-000
(Failed PCI Interface test)
1.
System Board
030-XXX-000
(Failed Internal SCSI interface
test)
1.
System Board
035-XXX-099
1.
No RAID adapters were found.
2.
If adapter is installed re-check connection.
035-XXX-S99
(Failed RAID test on PCI slot
S, check System Error Log before replacing
a FRU)
1.
RAID Adapter
2.
SCSI Backplane
3.
Cable
035-XXX-SNN
(Check System Error Log
before replacing a FRU, NN = SCSI ID of
failing fixed disk)
1.
Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.
035-253-S99
(RAID adapter initialization
failure)
1.
ServeRAID Adapter in slot S is not configured properly.
Obtain
the basic and extended configuration status and refer to the
ServeRAID Hardware Maintenance Manual for more information.
2.
Cable
3.
SCSI Backplane
4.
Adapter
Symptom-to-FRU index
123
Summary of Contents for 867413x - Eserver xSeries 330 8674
Page 2: ......
Page 93: ...Installing memory modules Complete the following steps to install a DIMM Installing options 85...
Page 165: ...Related service information 157...
Page 167: ...Related service information 159...
Page 169: ...Related service information 161...
Page 171: ...Related service information 163...
Page 183: ...Related service information 175...
Page 191: ......
Page 192: ...Part Number 24P2923 1P P N 24P2923...