100BASE-TX devices.
Table 20. Ethernet RJ-45 connector pin-number assignments.
Pin
Signal
Pin
Signal
1
Transmit data+
5
Not connected
2
Transmit data-
6
Receive data -
3
Receive data+
7
Not connected
4
Not connected
8
Not connected
Advanced System Management ports
There are two kinds of Advanced System Management ports: a Management port
(Serial port A), and RS-485 ports.
Management Port (Serial port A)
This port uses a standard D-shell serial-port connector, labeled A on the rear of the
server/workstation. You can attach a dedicated modem to the D-shell connector on
the rear of the server/workstation to communicate with the integrated Advanced
System Management Processor. For more information see “Serial port” on page 103.
RS-485 ports
The RS-485 ports on the rear of the server/workstation enable you to connect the
Advanced System Management Processors of several rack-mounted
server/workstations so that they can communicate with each other in half-duplex
mode.
Working with cables
The server has two different cabling options: the ASM bus and the Cable Chain
Technology (C2T). The following sections discuss each of these options. While
reading about these options, keep in mind that they are independent of each other.
108
Hardware Maintenance Manual: xSeries 330 Type 8674, IntelliStation R Pro Type 6851, and Network Equipment Building
System Type 8674
Summary of Contents for 867413x - Eserver xSeries 330 8674
Page 2: ......
Page 93: ...Installing memory modules Complete the following steps to install a DIMM Installing options 85...
Page 165: ...Related service information 157...
Page 167: ...Related service information 159...
Page 169: ...Related service information 161...
Page 171: ...Related service information 163...
Page 183: ...Related service information 175...
Page 191: ......
Page 192: ...Part Number 24P2923 1P P N 24P2923...