Error Code/Symptom
FRU/Action
01298001
(No update data for processor 1)
1.
Ensure all processors are the same stepping level and cache size.
2.
Processor 1
01298002
(No update data for processor 2)
1.
Ensure all processors are the same stepping level and cache size.
2.
Processor 2
01298101
(Bad update data for processor
1)
1.
Ensure all processors are the same stepping level and cache size.
2.
Processor 1
01298102
(Bad update data for processor
2)
1.
Ensure all processors are the same stepping level and cache size.
2.
Processor 2
I9990301
(Fixed boot sector error)
1.
Hard Disk Drive
2.
Cable
3.
SCSI Backplane
4.
System Board
I9990305
(Fixed boot sector error, no
operating system installed)
1.
Install operating system to hard disk drive.
I9990650
(AC power has been restored)
1.
Check power cable
2.
Check for interruption of power supply
3.
Power Cable
SCSI error codes
Error Code
FRU/Action
All SCSI Errors
One or more of the
following might be causing the problem:
v
A failing SCSI device (adapter, drive,
controller)
v
An improper SCSI configuration or SCSI
termination jumper setting
v
Duplicate SCSI IDs in the same SCSI
chain
v
A missing or improperly installed SCSI
terminator
v
A defective SCSI terminator
v
An improperly installed cable
v
A defective cable
1.
External SCSI devices must be powered-on before you power-on
the server/workstation.
2.
The cables for all external SCSI devices are connected correctly.
3.
If you have attached an external SCSI device to the
server/workstation, make sure the external SCSI termination is set
to automatic.
4.
The last device in each SCSI chain is terminated correctly.
5.
The SCSI devices are configured correctly.
Temperature error messages
Message
Action
DASD Over recommended Temperature
(sensor X)
(level-warning; DASD bay
″
X
″
had over temperature condition)
1.
Ensure system is being properly cooled
; see “Temperature
checkout” on page 25.
DASD under recommended temperature
(sensor X)
(level-warning; direct access
storage device bay
″
X
″
had under
temperature condition)
1.
Ambient temperature must be within normal operating
specifications
; see “Features and specifications” on page 4.
Symptom-to-FRU index
131
Summary of Contents for 867413x - Eserver xSeries 330 8674
Page 2: ......
Page 93: ...Installing memory modules Complete the following steps to install a DIMM Installing options 85...
Page 165: ...Related service information 157...
Page 167: ...Related service information 159...
Page 169: ...Related service information 161...
Page 171: ...Related service information 163...
Page 183: ...Related service information 175...
Page 191: ......
Page 192: ...Part Number 24P2923 1P P N 24P2923...