Error Code/Symptom
FRU/Action
089-XXX-001
(Failed Microprocessor test)
1.
Microprocessor 1
2.
System Board
089-XXX-002
(Failed Optional
Microprocessor test)
1.
Microprocessor 2
2.
System Board
165-060-000
(Service Processor: ASM may
be busy)
1.
Rerun the diagnostic test
2.
Fix other error conditions that may be keeping ASM busy. Refer to
the error log and diagnostic panel.
3.
Disconnect all server/workstation and option power cords from
server/workstation, wait 30 seconds, reconnect, and retry.
4.
System Board
165-198-000
(Service Processor: Aborted)
1.
Rerun the diagnostic test
2.
Fix other error conditions that may be keeping ASM busy. Refer to
the error log and diagnostic panel.
3.
Disconnect all server/workstation and option power cords from
server/workstation, wait 30 seconds, reconnect, and retry.
4.
System Board
165-201-000
(Service Processor: Failed)
1.
Disconnect all server/workstation and option power cords from
server/workstation, wait 30 seconds, reconnect, and retry.
2.
System Board. Before replacing the System Board, ensure that
System Board jumper J28 is not installed (the default) when the
error occurs.
165-330-000
(Service Processor: Failed)
1.
Update to the latest ROM diagnostic level, and retry.
165-342-000
(Service Processor: Failed)
1.
Ensure latest firmware levels for ASM and BIOS.
2.
Disconnect all server/workstation and option power cords from
server/workstation, wait 30 seconds, reconnect, and retry.
3.
System Board
180-XXX-000
(Diagnostics LED failure)
1.
Run Diagnostic LED test for the failing LED.
180-XXX-001
(Failed information LED panel
test)
1.
Switch Card / Information LED Panel
180-XXX-003
(Failed System Board LED
test)
1.
System Board
180-XXX-005
(Failed SCSI Backplane LED
test)
1.
SCSI Backplane
2.
SCSI Backplane Cable
3.
System Board
201-XXX-0NN
(Failed Memory test, see
″
Memory Settings
″
on page 30)
1.
DIMM Location slots 1-4 where NN = DIMM location.
Note:
NN 1=DIMM 1 NN 2=DIMM 2 NN 3=DIMM 3 NN
4=DIMM 4
2.
System Board
201-XXX-999
(Multiple DIMM failure, see
error text)
1.
See error text for failing DIMMs
2.
System Board
202-XXX-001
(Failed System Cache test)
1.
Microprocessor 1
2.
System Board
202-XXX-002
(Failed System Cache test)
1.
Microprocessor 2
2.
System Board
124
Hardware Maintenance Manual: xSeries 330 Type 8674, IntelliStation R Pro Type 6851, and Network Equipment Building
System Type 8674
Summary of Contents for 867413x - Eserver xSeries 330 8674
Page 2: ......
Page 93: ...Installing memory modules Complete the following steps to install a DIMM Installing options 85...
Page 165: ...Related service information 157...
Page 167: ...Related service information 159...
Page 169: ...Related service information 161...
Page 171: ...Related service information 163...
Page 183: ...Related service information 175...
Page 191: ......
Page 192: ...Part Number 24P2923 1P P N 24P2923...