Storage drive problems
Use this information to resolve storage drive problems.
Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v
See Chapter 4, “Parts listing,” on page 41 to determine which components are CRUs and which components
are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom
Action
Not all storage drives are
recognized by the Fixed Disk or
SAS Attached Disk diagnostic
test.
1.
Remove the storage drive that is indicated by the diagnostic tests. See
Chapter 5, “Removing and replacing blade server components,” on page 49.
2.
Run the SAS Fixed Disk or SAS Attached Disk diagnostic test again. See
“Diagnostic tools overview” on page 101.
3.
If the Fixed drive or SAS Attached Disk diagnostic test runs successfully,
replace the storage drive that you removed with a new one. See Chapter 5,
“Removing and replacing blade server components,” on page 49.
The blade server stops
responding during the Fixed
Disk or SAS Attached Disk
diagnostic test.
1.
Remove the storage drive that was being tested when the blade server stopped
responding. See Chapter 5, “Removing and replacing blade server
components,” on page 49.
2.
Run the SAS Fixed Disk or SAS Attached Disk diagnostic test again (see
“Diagnostic tools overview” on page 101).
3.
If the Fixed drive or SAS Attached Disk diagnostic test runs successfully,
replace the storage drive that you removed with a new one. See Chapter 5,
“Removing and replacing blade server components,” on page 49.
A storage drive passes the
Fixed Disk or SAS Attached
Disk diagnostics test, but the
problem remains.
1.
Run the SAS Fixed Disk or SAS Attached Disk diagnostic test again. See
“Diagnostic tools overview” on page 101.
2.
If the Fixed drive or SAS Attached Disk diagnostic test runs successfully but
the storage drive continues to have a problem, replace the drive with a new
one.
Intermittent problems
Use this information to resolve intermittent problems with the blade server.
Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
Chapter 6. Diagnostics
167
Summary of Contents for 7870B4U
Page 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 267: ......
Page 268: ...Part Number 90Y5614 Printed in USA 1P P N 90Y5614...