v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing,” on page 41 to determine which components are customer replaceable units
(CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
Error code
Description
Action
2010000
PCI-X PERR
1.
Reseat the expansion cards (see “Removing an
I/O expansion card” on page 71 and “Installing
an I/O expansion card” on page 75).
2.
Replace the following components one at a time
in the order shown, restarting the server each
time:
v
Expansion cards (see “Removing an I/O
expansion card” on page 71 and “Installing an
I/O expansion card” on page 75).
v
(Trained service technician only) Replace the
system board (see “Removing the
system-board assembly” on page 97 and
“Installing the system-board assembly” on
page 98).
2010001
PCI-X SERR
1.
Reseat the expansion cards (see “Removing an
I/O expansion card” on page 71 and “Installing
an I/O expansion card” on page 75).
2.
Replace the following components one at a time
in the order shown, restarting the server each
time:
v
Expansion cards (see “Removing an I/O
expansion card” on page 71 and “Installing an
I/O expansion card” on page 75).
v
(Trained service technician only) Replace the
system board (see “Removing the
system-board assembly” on page 97 and
“Installing the system-board assembly” on
page 98).
Chapter 6. Diagnostics
157
Summary of Contents for 7870B4U
Page 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 267: ......
Page 268: ...Part Number 90Y5614 Printed in USA 1P P N 90Y5614...