v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing,” on page 41 to determine which components are customer replaceable units
(CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
Error code
Description
Action
0058004
Mirror failover complete.
1.
Make sure that the DIMMs are installed in the
proper sequence (see “Installing a memory
module” on page 65).
2.
Reseat the DIMMs and restart the server (see
“Removing a memory module” on page 64 and
“Installing a memory module” on page 65).
3.
Remove each DIMM one at a time, restarting the
server after removing each DIMM until the error
is gone (see “Removing a memory module” on
page 64).
4.
Replace the failed DIMM; then, reinstall the
DIMMs to their original connectors and restart
the server (see “Installing a memory module” on
page 65).
5.
(Trained service technician only) Replace the
system board (see “Removing the system-board
assembly” on page 97 and “Installing the
system-board assembly” on page 98).
0058006
Spare copy failover complete.
1.
Make sure that the DIMMs are installed in the
proper sequence (see “Installing a memory
module” on page 65).
2.
Reseat the DIMMs and restart the server (see
“Removing a memory module” on page 64 and
“Installing a memory module” on page 65).
3.
Remove each DIMM one at a time, restarting the
server after removing each DIMM until the error
is gone (see “Removing a memory module” on
page 64).
4.
Replace the failed DIMM; then, reinstall the
DIMMs to their original connectors and restart
the server (see “Installing a memory module” on
page 65).
5.
(Trained service technician only) Replace the
system board (see “Removing the system-board
assembly” on page 97 and “Installing the
system-board assembly” on page 98).
0058007
Unsupported DIMM population
1.
Reseat the DIMMs and restart the server (see
“Removing a memory module” on page 64 and
“Installing a memory module” on page 65).
2.
Make sure that the DIMMs are installed in the
proper sequence (see “Installing a memory
module” on page 65).
154
BladeCenter HS22 Type 7870, 1936, and 1911: Problem Determination and Service Guide
Summary of Contents for 7870B4U
Page 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 267: ......
Page 268: ...Part Number 90Y5614 Printed in USA 1P P N 90Y5614...