v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing,” on page 41 to determine which components are CRUs and which components
are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error Code
Type
Error Message
Action
0x80010900
Error
Expansion Module 1 (BPE3 12V
Sense) voltage under critical
threshold. with chassis Reading:
X
, Threshold:
Y
1.
If the under voltage problem is occurring on all
blade servers, look for other events in the log
related to power and resolve those events (see
“Error logs” on page 103).
2.
View the event log provided by the advanced
management module for your BladeCenter unit
and resolve any power related errors that might
be displayed.
3.
If other modules or blades are logging the same
issue then check the power supply for the
BladeCenter unit.
4.
If the error continues, replace the Blade PCI
Express I/O expansion unit. See “Removing an
optional expansion unit” on page 84 and
“Installing an optional expansion unit” on page
85.
0x80010900
Error
Expansion Module 1 (BPE3
12VSB Sense) voltage over
critical threshold. Reading:
X
,
Threshold:
Y
1.
If the over voltage problem is occurring on all
blade servers, look for other events in the log
related to power and resolve those events.
2.
View the event log provided by the advanced
management module for your BladeCenter unit
and resolve any power related errors that might
be displayed.
3.
If other modules or blades are logging the same
issue then check the power supply for the
BladeCenter unit.
4.
If the error continues, replace the Blade PCI
Express I/O expansion unit. See “Removing an
optional expansion unit” on page 84 and
“Installing an optional expansion unit” on page
85.
0x80010900
Error
Expansion Module 1 (BPE3 3.3V
Sense) voltage under critical
threshold. with chassis Reading:
X
, Threshold:
Y
1.
If the under voltage problem is occurring on all
blade servers, look for other events in the log
related to power and resolve those events.
2.
View the event log provided by the advanced
management module for your BladeCenter unit
and resolve any power related errors that might
be displayed.
3.
If other modules or blades are logging the same
issue then check the power supply for the
BladeCenter unit.
4.
If the error continues, replace the Blade PCI
Express I/O expansion unit. See “Removing an
optional expansion unit” on page 84 and
“Installing an optional expansion unit” on page
85.
108
BladeCenter HS22 Type 7870, 1936, and 1911: Problem Determination and Service Guide
Summary of Contents for 7870B4U
Page 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 267: ......
Page 268: ...Part Number 90Y5614 Printed in USA 1P P N 90Y5614...