v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing,” on page 41 to determine which components are CRUs and which components
are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error Code
Type
Error Message
Action
0x80010900
Error
System board (Planar 12V)
voltage over critical threshold.
Reading:
X
, Threshold:
Y
1.
If the over voltage problem is occurring on all
blade servers, look for other events in the log
related to power and resolve those events.
2.
View the event log provided by the advanced
management module for your BladeCenter unit
and resolve any power related errors that might
be displayed.
3.
If other modules or blades are logging the same
issue then check the power supply for the
BladeCenter unit.
4.
If the error continues, replace the system-board
assembly (see “Removing the system-board
assembly” on page 97 and “Installing the
system-board assembly” on page 98).
0x80010900
Error
System board (Planar 3.3V)
voltage over critical threshold.
Reading:
X
, Threshold:
Y
Replace the blade (see “Removing the system-board
assembly” on page 97 and “Installing the
system-board assembly” on page 98).
0x80010900
Error
System board (Planar 5V)
voltage over critical threshold.
Reading:
X
, Threshold:
Y
1.
Remove all expansion cards from the blade server
(see “Removing an I/O expansion card” on page
71).
2.
Remove all storage drives from the blade server
(see “Removing a hot-swap storage drive” on
page 62).
3.
If the error continues, replace the system-board
assembly (see “Removing the system-board
assembly” on page 97 and “Installing the
system-board assembly” on page 98).
0x80010900
Error
System board (Inlet Temp)
temperature over/under critical
threshold with chassis reading:
X
, Threshold:
Y
1.
Make sure that the room temperature is within
the operating specifications (see “Features and
specifications” on page 9).
2.
Make sure that none of the air vents on the
BladeCenter unit and on the blade server are
blocked.
3.
Make sure that all of the fans on the BladeCenter
unit are running.
0x80010B00
Error
System board (Inlet Temp)
temperature over/under
non-recoverable threshold.
Reading: X, Threshold: Y
1.
Make sure that the room temperature is within
the operating specifications (see “Features and
specifications” on page 9).
2.
Make sure that none of the air vents on the
BladeCenter unit and on the blade server are
blocked.
3.
Make sure that all of the fans on the BladeCenter
unit are running.
Chapter 6. Diagnostics
109
Summary of Contents for 7870B4U
Page 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 267: ......
Page 268: ...Part Number 90Y5614 Printed in USA 1P P N 90Y5614...