v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing,” on page 41 to determine which components are CRUs and which components
are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error Code
Type
Error Message
Action
0x806F010C
Error
Group 1 (All DIMMs)
uncorrectable ECC memory
error
1.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory error.
2.
Manually re-enable all affected memory modules
if the server firmware version is older than UEFI
v1.10. If the server firmware version is UEFIv1.10
or newer, disconnect and reconnect the server to
the power source and restart the server.
3.
Install the affected memory modules (as indicated
by the error LEDs on the system board or the
event logs) to a different memory channel or
microprocessor (see “Installing a memory
module” on page 65 for memory population
sequence).
4.
If the error still occurs on the same memory
module, replace the affected memory module.
5.
(Trained service technician only) If the problem
occurs on the same DIMM connector, check the
DIMM connector. If the connector is damaged,
replace the system-board assembly (see
“Removing the system-board assembly” on page
97 and “Installing the system-board assembly” on
page 98).
6.
(Trained service technician only) Remove the
affected microprocessor and check the
microprocessor socket pins for any damaged pins.
If a damage is found, replace the system-board
assembly (see “Removing the system-board
assembly” on page 97 and “Installing the
system-board assembly” on page 98).
7.
(Trained Service technician only) Replace the
affected microprocessor (See “Removing a
microprocessor and heat sink” on page 90 and
“Installing a microprocessor and heat sink” on
page 94).
Chapter 6. Diagnostics
121
Summary of Contents for 7870B4U
Page 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 267: ......
Page 268: ...Part Number 90Y5614 Printed in USA 1P P N 90Y5614...