Error Code
Type
Error Message
Action
0x80010200
Error
System board (Planar 3.3V)
voltage under critical threshold.
Reading:
X
, Threshold:
Y
1.
Remove all expansion cards from the blade server
(see “Removing an I/O expansion card” on page
71).
2.
Remove all storage drives from the blade server
(see “Removing a hot-swap storage drive” on
page 62).
3.
If the error still occurs, replace the system-board
assembly (see “Removing the system-board
assembly” on page 97 and “Installing the
system-board assembly” on page 98).
0x80010200
Error
System board (Planar 5V)
voltage under critical threshold.
with chassis Reading:
X
,
Threshold:
Y
1.
Remove all expansion cards from the blade server
(see “Removing an I/O expansion card” on page
71).
2.
Remove all storage drives from the blade server
(see “Removing a hot-swap storage drive” on
page 62).
3.
If the error still occurs, replace the system-board
assembly (see “Removing the system-board
assembly” on page 97 and “Installing the
system-board assembly” on page 98).
0x80010200
Error
System board (Planar VBAT)
voltage under critical threshold.
with chassis Reading:
X
,
Threshold:
Y
Replace the system battery (see “Removing the
battery” on page 58 and “Installing the battery” on
page 60).
Note:
After you replace the system battery, verify
that the blade server is running IMM firmware
version 1.10 or newer to optimize the performance of
the new system battery.
0x80010700
Warning
System board (Inlet Temp)
temperature over/under
warning threshold. Reading:
X
,
Threshold:
Y
1.
Make sure that the room temperature is within
the operating specifications (see “Features and
specifications” on page 9).
2.
Make sure that none of the air vents on the
BladeCenter unit and on the blade server are
blocked.
3.
Make sure that all of the fans on the BladeCenter
unit are running.
Chapter 6. Diagnostics
107
Summary of Contents for 7870B4U
Page 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 267: ......
Page 268: ...Part Number 90Y5614 Printed in USA 1P P N 90Y5614...