Operation, Display and Application Examples
I5300 User Manual
- 72 -
Figure 4-30 Driving multiple motors
P
0-01 = 2
P
0-01 = 0 or 1
P
0-01 = 0 or 1
P
0-24
= 0
P
0-24
= 1
P
0-24
= 2
P
0-24
= 3
Motor 1 Motor 2 Motor 3 Motor 4
In the vector control mode , up to 4 motors
can be driven at different time . The motor
parameters are restored respectively .
In the vector control mode ,
multiple motors cannot be
driven simultaneously.
In the V/
F control mode
,
multiple motors can be
driven simultaneously.
4.10 Use of DI Terminals
The control board provides five DI terminals DI1 to DI5. You can obtain another DI terminals
DI6 to DI10 by installing an I/O extension card.
The internal hardware of DI terminals are configured with 24 VDC power supply for
detection. You can input a signal to a DI terminal of the AC drive only by shorting the DI
terminal and COM.
By default, P4-38 = 0000 and P4-39 = 0000. When a DI terminal is shorted to COM, it is
active (logic 1). When a DI terminal is not shorted to COM, it is inactive (logic 0).
You can change the DI terminal active mode. That is, a DI terminal is inactive (logic 0) when
being shorted with COM, and active (logic 1) when being not shorted to COM. In this case,
it is necessary to change the corresponding bit in P4-38 and P4-39 (these two parameters
respectively specifying the active mode setting of DI1 to DI5 and DI16 to DI10) to 1.
The AC drive also provides P4-10 (DI filter time) for the DI signal to improve the anti-
interference level. For DI1 to DI3, the AC drive provides the DI signal delay function,
convenient for some applications requiring delay.
Figure 4-31 DI delay setting
t
DI hardware
signal
Internal DI
signal
T
T
DI1
delay set in P
4-35
DI2
delay set in P
4-36
DI3
delay set in P
4-37
The preceding 10 DI terminals can be de
fi
ned in function codes
P
4-00 to
P
4-09. Each DI can be
allocated with their respective function from the 50 functions.
F
or details, see descriptions of
P
4-
00 to
P
4-09.
The hardware design allows only DI5 to receive high-speed pulse signal. If high-speed pulse
count is required, use DI5.
Summary of Contents for I5300 Series
Page 8: ......
Page 9: ...1 Safety Information and Precautions ...
Page 16: ...Safety Information and Precautions I5300 User Manual 16 ...
Page 17: ...2 Product Information ...
Page 28: ...Product Information I5300 User Manual 28 ...
Page 29: ...3 Mechanical and Electrical Installation ...
Page 45: ...4 Operation Display and Application Examples ...
Page 78: ...Operation Display and Application Examples I5300 User Manual 78 ...
Page 79: ...5 Function Code Table ...
Page 135: ...6 Description of Function Codes ...
Page 247: ...7 EMC ...
Page 255: ...8 Selection and Dimensions ...
Page 261: ...9 Maintenance and Troubleshooting ...