Description of Function Codes
I5300 User Manual
- 150 -
F
unction Code
Parameter Name
Setting Range
Default
P
1-28
Encoder type
0: A
BZ
incremental encoder
1: UVW incremental encoder
2: Resolver
3: SIN/COS encoder
4: Wire-saving UVW encoder
0
The I5300 supports multiple types of encoder. Different PG cards are required for different
types of encoder. Select the appropriate PG card for the encoder used. Any of the five
encoder types is applicable to synchronous motor. Only ABZ incremental encoder and
resolver are applicable to asynchronous motor.
After installation of the PG card is complete, set this parameter properly based on the actual
condition. Otherwise, the AC drive cannot run properly.
F
unction Code
Parameter Name
Setting Range
Default
P
1-30
A/
B
phase sequence of A
BZ
incremental encoder
0:
F
orward
1: Reserve
0
This parameter is valid only for ABZ incremental encoder (P1-28 = 0) and is used to set the
A/B phase sequence of the ABZ incremental encoder.
It is valid for both asynchronous motor and synchronous motor. The A/B phase sequence
can be obtained through "Asynchronous motor complete auto-tuning" or "Synchronous
motor no-load auto-tuning".
F
unction Code
Parameter Name
Setting Range
Default
P
1-31
Encoder installation angle
0.0°–359.9°
0.0°
This parameter is applicable only to synchronous motor. It is valid for ABZ incremental
encoder, UVW incremental encoder, resolver and wire-saving UVW encoder, but invalid for
SIN/COS encoder.
It can be obtained through synchronous motor no-load auto-turning or with-load auto-tuning.
After installation of the synchronous motor is complete, the value of this parameter must be
obtained by motor auto-tuning. Otherwise, the motor cannot run properly.
F
unction Code
Parameter Name
Setting Range
Default
P
1-32
U, V, W phase sequence of UVW
encoder
0:
F
orward
1: Reverse
0
P
1-33
UVW encoder angle offset
0.0°–359.9°
0.0°
These two parameters are valid only when the UVW encoder is applied to a synchronous
motor. They can be obtained by synchronous motor no-load auto-tuning or with-load auto-
tuning. After installation of the synchronous motor is complete, the values of these two
parameters must be obtained by motor auto-tuning. Otherwise, the motor cannot run
properly.
Summary of Contents for I5300 Series
Page 8: ......
Page 9: ...1 Safety Information and Precautions ...
Page 16: ...Safety Information and Precautions I5300 User Manual 16 ...
Page 17: ...2 Product Information ...
Page 28: ...Product Information I5300 User Manual 28 ...
Page 29: ...3 Mechanical and Electrical Installation ...
Page 45: ...4 Operation Display and Application Examples ...
Page 78: ...Operation Display and Application Examples I5300 User Manual 78 ...
Page 79: ...5 Function Code Table ...
Page 135: ...6 Description of Function Codes ...
Page 247: ...7 EMC ...
Page 255: ...8 Selection and Dimensions ...
Page 261: ...9 Maintenance and Troubleshooting ...