Function Code Table
I5300 User Manual
- 116 -
F
unction
Code
Parameter Name
Setting Range
Default
Property
A1-04 VDI5 function selection
0–59
0
★
A1-05 VDI state setting mode
Unit's digit (VDI1)
00000
★
0: Decided by state of VDOx
1: Decided by A1-06
Ten's digit (VDI2)
0, 1 (same as VDI1)
Hundred's digit (VDI3)
0, 1 (same as VDI1)
Thousand's digit (VDI4)
0, 1 (same as VDI1)
Ten thousand's digit (VDI5)
0, 1 (same as VDI1)
A1-06 VDI state selection
Unit's digit (VDI1)
00000
★
0: Invalid
1: Valid
Ten's digit (VDI2)
0, 1 (same as VDI1)
Hundred's digit (VDI3)
0, 1 (same as VDI1)
Thousand's digit (VDI4)
0, 1 (same as VDI1)
Ten thousand's digit (VDI5)
0, 1 (same as VDI1)
A1-07
F
unction selection for AI1
used as DI
0–59
0
★
A1-08
F
unction selection for AI2
used as DI
0–59
0
★
A1-09
F
unction selection for AI3
used as DI
0–59
0
★
A1-10 State selection for AI used
as DI
Unit's digit (AI1)
000
★
0: High level valid
1: Low level valid
Ten's digit (AI2)
0, 1 (same as unit's digit)
Hundred's digit (AI3)
0, 1 (same as unit's digit)
Summary of Contents for I5300 Series
Page 8: ......
Page 9: ...1 Safety Information and Precautions ...
Page 16: ...Safety Information and Precautions I5300 User Manual 16 ...
Page 17: ...2 Product Information ...
Page 28: ...Product Information I5300 User Manual 28 ...
Page 29: ...3 Mechanical and Electrical Installation ...
Page 45: ...4 Operation Display and Application Examples ...
Page 78: ...Operation Display and Application Examples I5300 User Manual 78 ...
Page 79: ...5 Function Code Table ...
Page 135: ...6 Description of Function Codes ...
Page 247: ...7 EMC ...
Page 255: ...8 Selection and Dimensions ...