I5300 User Manual Operation, Display and Application Example
- 67 -
Figure 4-27 Function code setting for fixed length control
P
4-04 = 27
(Length pulses
input)
DI5
P
4-00
to P
4-09
= 28
(Length reset)
PB
-07
(Number of
pulses per
meter)
Length pulses
Length reset
PB
-06
(Actual length)
PB
-05
(Set length)
≥
P
5-00
to P
5-05 = 10
(Length reached)
Reset
Clear to 0
÷
After the length is
reached, the DO
becomes 1.
Length reset input
Length reached output
Length pulses input
1 2 3
10 11 12
1 2
PB
-06 = 0
PB
-06 = 11
PB
-05 = 11
U0-13 (Length value)
U0-13 = 0
Note
•
In the
fi
xed length control mode, the direction cannot be identi
fi
ed and only the length shall be
calculated based on the number of pulses.
•
Only DI5 can be allocated with the function "Length count input".
•
An automatic stop system can be implemented if the length reached signal output by the DO is
fed back to the AC drive input terminal with the stop function.
Figure 4-28 Common application example of the fixed length control function
M
DI4
DI3
DI2
COM
P
4-03 = 26
,
P
4-04 = 27
PB
-07 (Number of
pulses per meter)
RUN button
JOG button
Length pulses input
CME
DI1
Stop button
DO1
Button for
clearing length
DI5
Length reached
output
Length
detection
sensor
Winding
motor
P
0-02 = 1
,
P
4-00 = 1
P
4-01 = 3
,
P
4-02 = 4
P
4-11 = 2
P
5-04 = 10
PB
-05 (Set length)
Summary of Contents for I5300 Series
Page 8: ......
Page 9: ...1 Safety Information and Precautions ...
Page 16: ...Safety Information and Precautions I5300 User Manual 16 ...
Page 17: ...2 Product Information ...
Page 28: ...Product Information I5300 User Manual 28 ...
Page 29: ...3 Mechanical and Electrical Installation ...
Page 45: ...4 Operation Display and Application Examples ...
Page 78: ...Operation Display and Application Examples I5300 User Manual 78 ...
Page 79: ...5 Function Code Table ...
Page 135: ...6 Description of Function Codes ...
Page 247: ...7 EMC ...
Page 255: ...8 Selection and Dimensions ...
Page 261: ...9 Maintenance and Troubleshooting ...