- 157 -
F
unction Code
Parameter Name
Setting Range
Default
P
3-01
Torque boost
0.0%–30%
Model
dependent
P
3-02
Cut-off frequency of
torque boost
0.00 Hz to maximum output
frequency
50.00 Hz
To compensate the low frequency torque characteristics of V/F control, you can boost the
output voltage of the AC drive at low frequency by modifying P3-01.
If the torque boost is set to too large, the motor may overheat, and the AC drive may suffer
overcurrent.
If the load is large and the motor startup torque is insuffcient, increase the value of P3-01.
If the load is small, decrease the value of P3-01. If it is set to 0.0, the AC drive performs
automatic torque boost. In this case, the AC drive automatically calculates the torque boost
value based on motor parameters including the stator resistance.
P3-02 specifies the frequency under which torque boost is valid. Torque boost becomes
invalid when this frequency is exceeded, as shown in the following figure.
Figure 6-4 Manual torque boost
Output
frequency
Output
voltage
Vb
fb
f1
V1
f1: Cutoff frequency of
manual torque boost
fb: Rated running
frequency
Vb: Maximum
output voltage
V1: Voltage of
manual torque boost
F
unction Code
Parameter Name
Setting Range
Default
P
3-03
Multi-point V/
F
frequency 1 (
F
1) 0.00 Hz to
P
3-05
0.00 Hz
P
3-04
Multi-point V/
F
voltage 1 (V1)
0.0%–100.0%
0.0%
P
3-05
Multi-point V/
F
frequency 2 (
F
2)
P
3-03 to
P
3-07
0.00 Hz
P
3-06
Multi-point V/
F
voltage 2 (V2)
0.0%–100.0%
0.0%
P
3-07
Multi-point V/
F
frequency 3 (
F
3)
P
3-05 to rated motor
frequency (
P
1-04)
Note: The rated frequencies
of motors 2, 3, and 4 are
respectively set in A2-04, A3-
04, and A4-04.
0.00 Hz
P
3-08
Multi-point V/
F
voltage 3 (V3)
0.0%–100.0%
0.0%
I5300 User Manual Description of Function Codes
Summary of Contents for I5300 Series
Page 8: ......
Page 9: ...1 Safety Information and Precautions ...
Page 16: ...Safety Information and Precautions I5300 User Manual 16 ...
Page 17: ...2 Product Information ...
Page 28: ...Product Information I5300 User Manual 28 ...
Page 29: ...3 Mechanical and Electrical Installation ...
Page 45: ...4 Operation Display and Application Examples ...
Page 78: ...Operation Display and Application Examples I5300 User Manual 78 ...
Page 79: ...5 Function Code Table ...
Page 135: ...6 Description of Function Codes ...
Page 247: ...7 EMC ...
Page 255: ...8 Selection and Dimensions ...
Page 261: ...9 Maintenance and Troubleshooting ...