N700E INSTRUCTION MANUAL
3-20
CF2
CF3
CF4
CF1
FW
0
0
0
1
0
0
0
1
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
F01
Frequency
0
0
0
0
A26
Jog Frequency
Range: 0.50 ~ 10.00 Hz in 0.01 Hz
Jogging frequency is used to move/rotate the motor in small increment at low frequency.
It is selected using input terminal.
Related Parameters: C01~ C12
A27
Jog Stop Mode
0: Free Run to Stop (Coast to Stop)
1: Deceleration to Stop
2: DC Injection Braking to Stop
Jogging frequency is used to move/rotate the motor in small increment at low frequency.
It is selected using input terminal.
Related Parameters: C01~C12
Programming Example:
A02 = 1; run by keypad (or A02=2; by Terminal)
F01 = Frequency Number @ CF4:CF1 = 0000
C01 ~ C05 (Assign to FW, JOG)
C07 ~ C12 (Assign Close/Open Polarity)
A11 ~ A25 ( Frequency Values)
A28
Torque Boost Mode
0: Manual Torque Boost (A29, A30)
1: Automatic Torque Boost (H02)
Select a torque boost mode. For V/F Control, compensate a beginning torque
by increasing the output voltage.
If selected Automatic Torque Boost mode, recommended the following
1. Run “Auto Tuning”
2. Use an auto tuning data(H02=1)
Related Parameters: H1~H11
JOG
FWD (Run)
REV
A26
A27
JOG
FWD
A26
Free Run
CM1 6
5
4
3
2
1 P24
JG
FW