N700E INSTRUCTION MANUAL
3-89
N700E
*Eu : Europe, *Am : America
FS : Factory Setting
*Data Type is unsigned integer16
Code
Number
Function Name
Address
(Hex)
Address
(Dec)
R/W
attribute
Init.
Value
Min.
Value
Max.
Value
Scale
Unit
b50
Load Balance Start
Frequency
0x0432
1075
R/W
0
0
40000
0.01
Hz
b51
Reserved Data
0x0433
1076
R/W
b52
Load Balance Gain
0x0434
1077
R/W
500
0
5000
0.01
b53
Load Balance Start Torque
0x0435
1078
R/W
0
0
1000
0.1
%
b54
Load Balance Frequency
Ramp Time
0x0436
1079
R/W
200
10
1000
0.1
Sec
b55
Load Balance Control
Mode
0x0437
1080
R/W
0
0
1
b56
System Load Detection
Selection
0x0438
1081
R/W
0
0
6
b57
System Overload
Detection Level
0x0439
1082
R/W
1000
200
2000
0.1
%
b58
System Underload
Detection Level
0x043a
1083
R/W
1000
200
2000
0.1
%
b59
System Detection Time
0x043b
1084
R/W
100
0
600
0.1
Sec
b60
System Detection Safe
Zone
0x043c
1085
R/W
0
0
A04
0.01
Hz
b61
Dwell Reference at Start
0x043d
1086
R/W
0
0
40000
0.01
Hz
b62
Dwell Time at Start
0x043e
1087
R/W
0
0
100
0.1
Sec
b63
Dwell Reference at Stop
0x043f
1088
R/W
0
0
40000
0.01
Hz
b64
Dwell Time at Stop
0x0440
1089
R/W
0
0
100
0.1
Sec