N700E INSTRUCTION MANUAL
3-11
Code
Name
Edit
Range
Unit Res Default
Output Terminal and related Function
C13 Output Relay 1
(AL0, AL1, AL2)
X 0: RUN
1: FA1
2: FA2
3: OL
4: OD
5: FLT
6: Operated by Communication
7: System Overload Detection
8: System Underload Detection
9:
System Overload/Underload Detection
-
-
5
C14 Output Relay 2 (RN0-RN1)
X
-
-
1
C15 Output Relay 3 (RN2-RN3)
X
-
-
0
C16 Output Relay 2 (RN0-RN1)
Mode
X 0: Normally Open [NO]
1: Normally Closed [NC]
-
-
0
C17 Output Relay 3 (RN2-RN3)
Mode
X 0: Normally Open [NO]
1: Normally Closed [NC]
-
-
0
C18 FM Output Setting
X
0: Output Frequency Monitor
1: Output Current Monitor
2: Output Voltage Monitor
3: Output Power Monitor
4: Output Torque Monitor
5: Operated by Communication
-
-
0
C19 FM Gain
O 0.0 to 250.0
%
0.1 100.0%
C20 FM Offset
O -3.0 to 10.0
%
0.1
0.0%
C21 Motor Overload Alarm
X 10.0 to 200.0
%
0.1 100.0%
C22 FA2 SetPoint at Acceleration
X 0.00 to Max Frequency (A04)
Hz 0.01 0.00Hz
C23 FA2 SetPoint at Deceleration
X 0.00 to Max Frequency (A04)
Hz 0.01 0.00Hz
C24 PID Error Tolerance
X 0.0 to 100.0
%
0.1 10.0%
C25 AMI Output Setting
X
0: Output Frequency Monitor
1: Output Current Monitor
2: Output Voltage Monitor
3: Output Power Monitor
4: Output Torque Monitor
5: Operated by Communication
-
-
1
C26 AMI Gain
O 0.0 to 250.0
%
0.1 100.0%
C27 AMI Offset
O -99.9 to 100.0
%
0.1
0.0%
C28 UP/DOWN Initial Value Saving
X 0: Disabled
1: Enabled
-
-
0
C29 UP/DOWN Initial Value Setting
X 0.00 to A04
Hz 0.01 60.00
C30 UP/DOWN Reference Arriving
Time
X 0.1 to 3000
Sec 0.1
10.0