N700E INSTRUCTION MANUAL
3-60
Set 24: Frequency Override (FO)
Set 25: Reset Override (RO)
Frequency Override is a manual frequency adder enables adding a frequency value to the target
frequency setpoint. Since it is an edge triggered signal, it stays activated till Reset Override signal is
provided. Once RO is activated, VFD frequency output follows back to the target value in F01.
Code
Set Value
Description
A02
1
Run command by Terminal Input
C01
0
Set Terminal 1 to Forward Run
C05
24
Set Terminal 5 to Manual Frequency Adder
C06
25
Set Terminal 6 to Reset Override
C07
0
Terminal 1 to Normal Open
When Shorted(Closed): FW Run, When Open: FW Stop
C11
0
Terminal 5 to Normal Open
C12
0
Terminal 6 to Normal Open
F01
[0.5 ~ Max Hz] Output Frequency Setting
A11
[0.5 ~ F04 Hz] 1st Multi Speed Frequency (Shared with this function)
CM1
6
P24
RO
FW
5
4
3
2
1
VFD F Out
FW(Run)
Reset Override (RO)
FO
F
Target
(F01)
F
Target
(F01) + A11
Frequency Override (FO)
Set 26: External Trip 2 (EXT2)
Set 27: External Trip 3 (EXT3)
Set 28: External Trip 4 (EXT4)
Set 29: External Trip 5 (EXT5)
Set 30: External Trip 6 (EXT6)
In addition to External Trip in Set 10, five more external trip signals are provided for flexible control
of corresponding function.
Code
Set Value
Description
C01
1
Run command by Terminal Input
C02
26
Set Terminal 2 to External Trip 2
C03
27
Set Terminal 3 to External Trip 3
C04
28
Set Terminal 4 to External Trip 4
C05
29
Set Terminal 5 to External Trip 5
C06
30
Set Terminal 6 to External Trip 6
C07~C12
0
Terminal 1~6 Normal Open
When Shorted(Closed): FW Run, When Open: FW Stop