PARAMETER 02:
Receiver Computer
Type
RECEIVER TYPE FBI MM/DD/YY HH:MM:SS
Background:
Like the CP-220A, the hardware and software used with an
Automation
System
must also be customized to perform properly in the Central Station.
In terms of its software, most automation "packages" need to know which
Central Station Receiver will be providing the data to be processed.
Although the CP-220A is considered to be an
FBI
Receiver, it has the ability
to emulate the receivers of two other manufacturers: the
RADIONICS 6000
and the
ADEMCO 685.
Use
PARAMETER 02
if you either require, or
desire, to change the CP-220A's "receiver emulation."
Choosing a receiver emulation other than
FBI
imposes certain restrictions
on the
Reporting Formats
the CP-220A can process. The table below shows
the restrictions imposed by selecting either
ADEMCO
or
RADIONICS
in
this parameter. A listing of all the
Reporting Formats
capable of being
processed by the CP-220A is detailed in
Appendix B.
SELECTING RADIONICS OR ADEMCO FOR PARAMETER 02
RECEIVER
FORMATS WHICH CAN BE PROCESSED
FORMATS WHICH CAN'T BE PROCESSED
RADIONICS
•all pulsed formats with 3-digit Account Numbers
•all RADIONICS-based formats
•formats using 4-digit Account Numbers
•ADEMCO-based formats:
•High-Speed •Express
•
Contact I.D.
•FBI Superfast
•ACRON Superfast
•SILENT KNIGHT FSK
•SESCOA Fast
ADEMCO
•all pulsed formats
•all ADEMCO-based formats
•RADIONICS BFSK formats
•FBI Superfast
•ACRON Superfast
•SESCOA Fast
•SILENT KNIGHT FSK
NOTE 1: If this parameter is left as factory programmed (
FBI
), all formats that the receiver is
capable of processing (see
Appendix B
) will be accepted by any and all Line Cards used in
the CP-220A. Unless there are compelling reasons to do otherwise, select
FBI
for
PARAMETER 02.
NOTE 2: Leave
PARAMETER 02
as factory programmed (
FBI
) if no
Automation System
is
being used.
Programming Procedures:
Use the
NEXT
key or the
MANUAL/PREVIOUS
key to alternate among
[FBI], [RADIONICS], and [ADEMCO].
Default:
PARAMETER 02
is defaulted to [FBI].
Page 2-76 Section 2: Programming the CP-220A CP-220A Central Station Receiver
Hook-Up and Installation Manual
Advancing to Next Parameter: