Preparation for
Programming:
External
Connections
Have Been Made
LINE CARD 8 OPERATIVE PRINTER FAIL
LINE CARD 8 OPERATIVE LINE FAULT 1
LINE CARD 8 OPERATIVE LINE FAULT 8
NOTE: LINE FAULT messages like those illustrated above result when the
CP-220A checks for active telephone service at each Line Card but
fails to find it.
5. Once the NEXT LED remains off, there are no more messages to
acknowledge. At this point it will be possible to enter the Programming
Mode.
NOTE: Even though the previous faults are now acknowledged, they
remain uncorrected and will be annunciated again every 15
minutes (approximately) until they are remedied. When in the
Programming Mode, however, fault annunciation is
suspended
and
will not re-occur until the Programming Mode has been exited. At
that time, uncorrected faults will continue to be annunciated as
described above.
Proceed to
Entering and Using the Programming Mode
on page 2-5.
If you have already made the
battery
,
printer
, and
telephone line
connections
to your CP-220A, you are ready to enter the Programming Mode. First,
perform the following preliminary actions:
1.
Insert the CP-220A's AC Line Cord into an
unswitched
electrical outlet
supplying 120 Volts AC at 60 Hertz.
During the next 25 seconds (approximately) while the CP-220A performs
some self-checks, its internal sounder will annunciate and several relay
activations may be heard. The MANUAL/PREVIOUS LED will
illuminate, and the NEXT LED will light soon after.
2.
At this point, check that your CP-220A's display appears like this:
SYSTEM RESET VER 3.91 01/01/00 00:00:25
Page 2-4
Section 2: Programming the CP-220A CP-220A Central Station Receiver
Hook-Up and Installation Manual